00198382-03_UM_SIPLACE-CA4-V2_EN.pdf - 第200页
5 Tasks at the placement machine Instruction manual SIPLACE CA4 V2 5.3 Switching the SIPLACE CA4 V2 on From software version 713.0 E dition 12/2019 200 5 Fig. 5.3 - 1 "Production" view after loading the station…

Instruction manual SIPLACE CA4 V2 5 Tasks at the placement machine
From software version 713.0 Edition 12/2019 5.3 Switching the SIPLACE CA4 V2 on
199
5.3 Switching the SIPLACE CA4 V2 on
5.3.1 What to consider before switching on the stations
5
Check whether the stations are connected to the power and compressed air supplies.
Perform a sight check of the stations. Make sure that there are no obstacles in the travel
range of the gantries.
Make sure that the Z axes of all heads are in their uppermost end positions.
5.3.2 User classification
Certain functions or menus may only be executed or can only accessed by specially trained per-
sonnel. A differentiation is made between the following operator levels:
– Production
– Advanced production
– Service (customer)
The operator levels "Advanced production" and "Service (customer)" can be password protected.
For a detailed description of the user classification, refer to section 5.1
, page 193.
5.3.3 Switching on the station and starting the station software user interface
Switch the station on at the main power switch.
After switching on, check whether the manometers show the required operating pressure.
The station computer software is loaded and the "Production" view of the station software is
shown for the "Production" operator level (see following diagram).
CAUTION
Before you switch on the stations, please perform the following steps.

5 Tasks at the placement machine Instruction manual SIPLACE CA4 V2
5.3 Switching the SIPLACE CA4 V2 on From software version 713.0 Edition 12/2019
200
5
Fig. 5.3 - 1 "Production" view after loading the station software (example)
The status field (see section 5.5.1, page 204) shows the current status of the station and the action
to be performed.
Press the start button when you see the request "Press Start button".
The start buttons are located on the control panels at the left and right of the station.
A reference run will be performed. After the reference run has been completed, the station is
ready for operation and will wait for production data or for printed circuit boards.
The icon will be shown in the working area of the user interface (enabled).
Press the icon to start production.

Instruction manual SIPLACE CA4 V2 5 Tasks at the placement machine
From software version 713.0 Edition 12/2019 5.3 Switching the SIPLACE CA4 V2 on
201
5.3.4 Action of placement machine start button
The action performed by the start button can be set.
Open the "Check sensors and functions" view (see section 5.5.3, page 205).
The following settings are possible:
Start production automatically 5
Standard setting.
Pressing the start button automatically begins the production process.
Do not change production status 5
This is used, for example, to calibrate and test the placement machine
Pressing the start button simply closes the electricity circuit; production is not started immediately.
5
CAUTION
Machine functions can be directly started via the GUI, irrespective of the start button set-
ting. If the electrical circuit has already been closed, you do not need to confirm with the
placement machine start button.