00198382-03_UM_SIPLACE-CA4-V2_EN.pdf - 第201页
Instruction manual SIPLACE CA4 V 2 5 Tasks at the placement machi ne From software version 713.0 Ed ition 12/2019 5.3 Switching the SIP LACE CA4 V2 on 201 5.3.4 Action of placeme nt machine start button The action perfor…

5 Tasks at the placement machine Instruction manual SIPLACE CA4 V2
5.3 Switching the SIPLACE CA4 V2 on From software version 713.0 Edition 12/2019
200
5
Fig. 5.3 - 1 "Production" view after loading the station software (example)
The status field (see section 5.5.1, page 204) shows the current status of the station and the action
to be performed.
Press the start button when you see the request "Press Start button".
The start buttons are located on the control panels at the left and right of the station.
A reference run will be performed. After the reference run has been completed, the station is
ready for operation and will wait for production data or for printed circuit boards.
The icon will be shown in the working area of the user interface (enabled).
Press the icon to start production.

Instruction manual SIPLACE CA4 V2 5 Tasks at the placement machine
From software version 713.0 Edition 12/2019 5.3 Switching the SIPLACE CA4 V2 on
201
5.3.4 Action of placement machine start button
The action performed by the start button can be set.
Open the "Check sensors and functions" view (see section 5.5.3, page 205).
The following settings are possible:
Start production automatically 5
Standard setting.
Pressing the start button automatically begins the production process.
Do not change production status 5
This is used, for example, to calibrate and test the placement machine
Pressing the start button simply closes the electricity circuit; production is not started immediately.
5
CAUTION
Machine functions can be directly started via the GUI, irrespective of the start button set-
ting. If the electrical circuit has already been closed, you do not need to confirm with the
placement machine start button.

5 Tasks at the placement machine Instruction manual SIPLACE CA4 V2
5.4 Switching the SIPLACE CA4 V2 off From software version 713.0 Edition 12/2019
202
5.4 Switching the SIPLACE CA4 V2 off
5
5.4.1 Switching off the stations
To switch off the stations, proceed as follows:
End all placement procedures, so that there are no more boards in the placement machine.
Check whether the Z axes of all placement heads are in their uppermost end positions.
Check whether there are still components on the placement heads and remove these.
Close the station computer software in the view
Settings --> Machine Settings --> Shut Down Machine...
Once the computer has been shut down, switch off the station at the main switch.
CAUTION