00198382-03_UM_SIPLACE-CA4-V2_EN.pdf - 第197页
Instruction manual SIPLACE CA4 V 2 5 Tasks at the placement machi ne From software version 713.0 Ed ition 12/2019 5.2 Controls and disp lays 197 5.2 Controls and displays 5.2.1 Overview 5 Fig. 5.2 - 1 Controls and displa…
5 Tasks at the placement machine Instruction manual SIPLACE CA4 V2
5.1 Staff profiles From software version 713.0 Edition 12/2019
196
5.1.3 Operator level "Service (customer)"
5.1.3.1 Tasks
The service personnel's duties include:
– Major preventive maintenance jobs
– Mounting replacement parts
– Editing machine data
– Calibrating the placement machine

Instruction manual SIPLACE CA4 V2 5 Tasks at the placement machine
From software version 713.0 Edition 12/2019 5.2 Controls and displays
197
5.2 Controls and displays
5.2.1 Overview
5
Fig. 5.2 - 1 Controls and displays
(1) Main switch (5) Start button (white)
(2) Stop button (black) (6) LCD touchscreen
(3) EMERGENCY STOP button (7) Indicator lamps with buzzer
(4) Keyboard (optional) (T) Direction of PCB conveyor
(1)
(2)
(3)
(5)
(6)
(7)
(7)
(4)

5 Tasks at the placement machine Instruction manual SIPLACE CA4 V2
5.2 Controls and displays From software version 713.0 Edition 12/2019
198
5.2.2 Description
All the controls can be reached by a 1.40 m tall person.
Main switch 5
The main power switch is used to switch the power supply to the placement machine on and off.
5
Stop button, black 5
This black button is used to stop the placement process at the placement machine.
Start button (white) 5
This white button starts the placement machine after it has been switched on or after faults have
been eliminated.
EMERGENCY STOP button 5
The EMERGENCY STOP button latches in the ON position when pressed. The power supply to
the gantry axes, the component trolleys, conveyors and used tape cutters is interrupted and the
voltage supplied to the star axes of the placement heads is reduced. Turn the button to release it.
LCD touchscreen 5
There is a flat LCD screen with a touch-sensitive surface (touchscreen) on either side of the place-
ment machine.
Keyboard 5
The keyboard is located beneath the monitor.
Indicator lamp with buzzer - three color 5
The sequence of colors of the indicator lamps is red - yellow - green. These lamps are used to
signal operating statuses and malfunctions of the placement machine. See also Section 5.7 on
page 215.
DANGER
Lethal voltages!
Some parts inside the placement machine carry potentially lethal voltages - even when
switched off at the main power switch. See also section 2.6.3.3
, page 77.