021 1-005 Chapter 1 3 - 18 Tg0582-PM-D1 1.4 Stop and Re-Start Procedures of Automatic Operation 1.4 Stop and Re-Start Procedures of Automatic Op- eration 1.4.1 Replenishment of Components and P .C.B.’s While the machine …

(10) When the [START] button on the front operation panel is pressed,
the automatic operation (printing) starts.
When the automatic operation (printing) starts, all origin marks ""
disappear and the LED (green) of the [START] button and the tower
light (green) illuminate.
(a) The machine cannot be started unless the "AUTO OP-
ERATION" window (Main Menus) is active.
(b) When a P.C.B. already exists in the P.C.B. positioning sec-
tion, the machine discharges the P.C.B. without printing
any solder paste on the P.C.B.(10) When the [START]
button on the front operation panel is pressed, the auto-
matic operation (printing) starts.
0211-005
Chapter 1 3-17 Tg0582-PM-D1
1.3 Start of Automatic Operation
Fig. 1C29

0211-005 Chapter 1 3-18 Tg0582-PM-D1
1.4 Stop and Re-Start Procedures of Automatic Operation
1.4 Stop and Re-Start Procedures of Automatic Op-
eration
1.4.1 Replenishment of Components and P.C.B.’s
While the machine is in the automatic operation stop mode or stopped
temporarily (pause mode), the squeegees can be replaced or solder
paste can be replenished during automatic operation.
• Automatic Operation Stop
When the number of printing operations reaches the rate (percent-
age) specified for "Squeegee Limit Stop Setting" in the "Auto Stop
Setting" tab sheet during automatic operation, an error alarm is is-
sued and the machine stops running. In this case, follow the steps
below to replace the squeegees and re-start the automatic opera-
tion.
(1) Press the [RESET] button to cancel the error alarm.
(2) When the [PRODUCT CHG.] button on the submenu bar is pressed
and the [Squeegee Change] tab is selected, the following window
appears on the screen.
(3) When the [Sqg. Chg. Pos. Move (START)] button is selected and
the [START] button on the front operation panel is pressed, the
squeegees move to the cleaning position.
Fig. 1C30

0211-005 Chapter 1 3-19 Tg0582-PM-D1
1.4 Stop and Re-Start Procedures of Automatic Operation
Mechanical Valve Switch
Squeegee
(4) Set the [OPERATION/SET UP] switch on the front operation panel
to "SET UP".
(5) Open the front safety door.
(6) Push down the mechanical valve switch (used to clamp the squee-
gee) to the left side (state of unclamping) and pull down the squee-
gee from the squeegee holder to detach.
Fig. 1C31
(7) While pushing the squeegee (one to be replaced) tightly against
the lower surface of the squeegee holder, push down the mechani-
cal valve switch to the right side to clamp the squeegee.
(a) Hold the squeegee securely and attach it.
If the squeegee falls down on the screen, the screen
may be damaged.
It is recommended that a protective plate should be
placed on the screen.
(b) The squeegee should be clamped from the rear side
of the holder and then from the front side.