1OM-1086-002.pdf - 第302页
(3) When the coordinate teaching operation starts, the coordinate data is displayed as shown in Fig. 2F33. As for this data, the P .E.C. recognition mark data of the operation data is reflected. If necessary , enter the …

6.2.1 Procedure for Coordinate Teaching Operation
(1) Set a P.C.B. to the dummy P.C.B. input location. Select the [PCB
Clamp (START)] button and press the [START] button on the front
operation panel.
The P.C.B. is transferred from the dummy P.C.B. input location
and positioned.
(2) Select the [Ref. Mark Pos. Move (START)] button and press the
[START] button on the front operation panel.
The P.C.B. reference mark appears on the "Camera Center" pane
as shown in the figure below.
Select the [Eye Adjust (START)] button and press the [START]
button until the P.C.B. reference mark is located over the cross
hairs.
After the manual alignment operation, press the [CLOSE] button.
Fig. 2F34
6.2 "Coordinate Teaching" Tab
0211-005 Chapter 2 6-44 Tg0582-PM-D1

(3) When the coordinate teaching operation starts, the coordinate data
is displayed as shown in Fig. 2F33.
As for this data, the P.E.C. recognition mark data of the operation
data is reflected.
If necessary, enter the approximate values (X and Y coordinates
measured beforehand) for "Fiducial Mark #1" and "Fiducial Mark
#2" of the P.E.C. and screen recognitions, using the "Tenkey" pad.
The mark data can also be edited by pressing the [Mark Data] key
corresponding to each mark teaching operation.
Refer to "6.2.2 Editing of Recognition Mark Data" for details.
Select the [P.E.C. Recog. Mark 1 Move (START)] button and press
the [START] button on the front operation panel.
The P.E.C. recognition camera moves to the specified mark posi-
tion.
A P.E.C. recognition mark appears on the camera monitor as shown
in the figure below.
Select the [Eye Adjust (START)] button and press the [START]
button (manual alignment operation) until the recognition mark
comes over the outline located at the center of the (Camera Moni-
tor) pane.
After the manual alignment operation, press the [CLOSE] button.
Refer to "6.2.3 Manual Alignment Operation" for how to perform
the manual alignment operation.
Fig. 2F35
(4) Perform the same manual alignment operation for "P.E.C. Recog-
nition Mark 2".
(5) To make both P.E.C. and screen recognition coordinate data iden-
tical to each other, select the [↓ COPY] button.
The parameters obtained through the teaching operation of the
P.E.C. recognition coordinates are copied and pasted as those for
"Screen Recog. Posn.".
6.2 "Coordinate Teaching" Tab
0211-005 Chapter 2 6-45 Tg0582-PM-D1

(6) Select the [Screen Recog. Mark 1 Coordinate Teaching (START)]
button and press the [START] button on the front operation panel.
The P.E.C. recognition camera moves to the coordinates on the
P.C.B. (the coordinates for screen recognition).
Perform the same manual alignment operation as "P.E.C. Recog-
nition Mark 1" on "Screen Recognition Mark 1".
(The coordinate data is displayed on the camera monitor (similar
to "(3)").)
(7) Select the [Screen Recog. Mark 1 Move (START)] button and press
the [START] button on the front operation panel.
The screen recognition camera moves to the coordinates that were
taught in "(6)".
After the end of the movement, select the [Recog. Test Exec.
(START)] button and press the [START] button to perform a recog-
nition test if necessary.
(8) Perform the same operation for "Screen Recognition Mark 2".
(9) Press the [Data Save] button to save the results of the teaching
operations.
This data is reflected on the P.E.C. recognition mark data of the
operation data.
(10) Select the [Unit Return (START)] button and press the [START]
button on the front operation panel. The original condition resumes.
6.2 "Coordinate Teaching" Tab
0211-005 Chapter 2 6-46 Tg0582-PM-D1