1OM-1086-002.pdf - 第321页
Movement to Assigned Position Select the [Assign. Posn. Move (ST ART)] button for "Fiducial Mark #2" (Second P .E.C. Recognition Mark). • Press the "X" or the "Y" data box under "Recog.…

7.1.3 Camera Movement Operation
Select the [Camera X-Y Move] button.
The "P.E.C. Recog. Camera Move Opn. Scrn." window (Fig. 2F51)
opens.
Fig. 2F51
Manual Alignment Operation
Select the [Eye Adjust (START)] button for "Fiducial Mark #1" (First
P.E.C. Recognition Mark).
• Specify the direction with the [ ], the [ ], the [ ], or the [ ] button.
• Specify the speed with the [HIGH], the [LOW], or the [1 PULSE] but-
ton.
• Press the [START] button on the front operation panel and move the
P.E.C. recognition mark to the position in the recognition area where
the mark should be recognized.
While the [START] button on the front operation panel is being
pressed, the camera keeps on moving.
• Press the [CLOSE] button. The tab sheet (Fig. 2F47) resumes.
7.1
"
P.E.C. Recog. Test
"
Tab
0211-005 Chapter 2 6-63 Tg0582-PM-D1

Movement to Assigned Position
Select the [Assign. Posn. Move (START)] button for "Fiducial Mark #2"
(Second P.E.C. Recognition Mark).
• Press the "X" or the "Y" data box under "Recog. Camera Move Posn.
Assign.". A ten-key window appears. Enter a value, using the panel.
Press the [AC] button whenever it is necessary to clear the data.
With the [#1 Pos.] or [#2 Pos.] buttons, the designated coor-
dinates in the pattern program can be copied in the "Recog.
Camera Move Posn. Assign." data boxes.
• When the [START] button on the front operation panel is pressed,
the P.E.C. recognition camera moves to the assigned position.
• Press the [Eye Adjust (START)] button to perform the same opera-
tion as "Manual Alignment" and move the P.E.C. recognition mark to
the position where the mark should be recognized.
7.1
"
P.E.C. Recog. Test
"
Tab
0211-005 Chapter 2 6-64 Tg0582-PM-D1
Fig. 2F51-1

7.1.4 Camera Monitor
When the "P.E.C. Recog. Test" tab sheet becomes active, a recognition
area appears on the camera monitor.
When the setting of the recognition area is changed, the dis-
play area also changes.
Fig. 2F52
• When the recognition is made normally, the table moves, the image
of the fiducial mark moves to the camera center, and the outline of
the mark shape and the cross hairs appear in the window (recogni-
tion area).
The positional deviation (X and Y) of the fiducial mark from the cam-
era center is displayed in the "A"-marked area of the window.
The displayed positional deviation shows the deviation de-
tected before testing.
Fig. 2F53
The point of the cross hairs intersection is the camera center.
• When the results of the recognition is "NG (No Good)", the outline of
the mark shape and the cross hairs do not appear and an error mes-
sage (recognition error) is issued on the touch screen.
7.1
"
P.E.C. Recog. Test
"
Tab
X Y
A
Image of
Fiducial Mark
Recognition Range (Area)
Outline of Mark Shape
Window (Recognition Area)
Cross Hairs
0211-005 Chapter 2 6-65 Tg0582-PM-D1