1OM-1086-002.pdf - 第295页

6.1.2 Camera X-Y Move When the [Camera X-Y Move] button is pressed in the "Inaccurate Posn. Correction" tab sheet, the following window (Fig. 2F29) opens. Fig. 2F29 There are two ways to move the camera to a re…

100%1 / 355
*2 "Setting"
When the [Data Save] button is pressed, the set values are en-
tered.
*3 [Posn. Correction Execute (START)] Button
When this button is pressed, positional deviations are corrected.
*4 [Unit Return Execute (START)] Button
When this button is pressed, each unit is zeroed.
*5 [Alignment (START)] Button
When this button is pressed, the screen and the P.C.B. are aligned
with each other.
*6 [Camera X-Y Move] Button
When this button is pressed, the "Screen Recog. Camera Move
Opn. Scrn." window opens.
6.1.1 Procedure for Inaccurate Position Correction
(1) Set a P.C.B. to the dummy P.C.B. input location.
(2) When the [Posn. Correction Execute (START)] button is selected
and the [START] button on the front operation panel is pressed,
the machine starts the position correction operation.
After transferring the P.C.B. at the dummy P.C.B. input location
and positioning it, move the table under the screen so that the
machine is set ready for the manual alignment operation, using the
screen recognition camera.
(3) When the [Camera X-Y Move] button is pressed, the "Screen
Recog. Camera Move Opn. Scrn." window opens.
Move the recognition camera to the coordinates (positioning point)
of a recognition mark (a foot pattern, etc.).
Refer to "6.1.2 Camera X-Y Move" for details.
(4) When the [Alignment (START)] button is pressed, the window for
adjustment of the screen and table positions opens.
Refer to "6.1.3 Alignment Operation" for details.
(5) When the [Unit Return Execute (START)] button is selected and
the [START] button on the front operation panel is pressed after
the end of the above-described operations, each unit is zeroed.
6.1 "Inaccurate Posn. Correction" Tab
0211-005 Chapter 2 6-37 Tg0582-PM-D1
6.1.2 Camera X-Y Move
When the [Camera X-Y Move] button is pressed in the "Inaccurate Posn.
Correction" tab sheet, the following window (Fig. 2F29) opens.
Fig. 2F29
There are two ways to move the camera to a recognition mark (or a
pattern).
••
••
• Manual Alignment
(1) Select the [Eye Adjust (START)] button.
(2) Press one of the "DIRECTION" button to select a direction and
select one of the "SPEED" buttons to specify a speed.
(3) When the [START] button on the front operation panel is pressed,
the camera starts moving in the designated direction at the speci-
fied speed.
While the [START] button is kept pressed, the camera keeps on
moving.
(4) After the camera has moved to the recognition mark (or the pat-
tern), press the [Close] button. The previous window appears.
Fig. 2F30
0211-005 Chapter 2 6-38 Tg0582-PM-D1
Direction of Camera X Movement
Camera X
Camera
Direction of Camera
Y Movement
Camera Y
6.1 "Inaccurate Posn. Correction" Tab
••
••
• Movement to Specified Position
(1) Select the [Assign. Posn. Move (START)] button.
The window (Fig. 2F31) opens.
(2) Select the [X] and [Y] buttons entitled "Recog. Camera Move Posn.
Assign." and enter parameters using the ten-key pad.
(3) When the [START] button on the front operation panel is pressed,
Table X/Y moves to the recognition mark (foot pattern, etc.) lo-
cated at the specified position.
Fig. 2F31
(4) After the above-described operation, press the [CLOSE] button.
The previous window (Fig. 2F29) opens.
6.1 "Inaccurate Posn. Correction" Tab
0211-005 Chapter 2 6-39 Tg0582-PM-D1