1OM-1086-002.pdf - 第308页
(3) Press the [Eye Adjust] button. The following window (Fig. 2F39) opens. Fig. 2F39 The upper end face of the vacuum plate appears on the camera monitor as shown below . Perform the manual alignment operation such that …

*2 "Operating Unit Selection Button"
[JIG Upper End Cam. Move (START)] Button
When this button is selected and the [START] button on the front
operation panel is pressed with the status indicator showing "ON
(Operation Possible)", the P.E.C. recognition camera starts mov-
ing and the upper end face of the vacuum plate appears in the
"Recognized Image" window.
[JIG Lower End Cam. Move (START)] Button
When this button is selected and the [START] button on the front
operation panel is pressed with the status indicator showing "ON
(Operation Possible)", the P.E.C. recognition camera starts mov-
ing and the lower end face of the vacuum plate appears in the
"Recognized Image" window.
*3 [Eye Adjust] Button
When this button is pressed, the "Camera X Move Opn. Scrn."
window opens.
*4 [Unit Return Execute (START)] Button
When this button is selected and the [START] button on the front
operation panel is pressed with the status indicator showing "ON
(Operation Possible)", each unit is zeroed.
6.3.1 Procedure for Teaching Operation on Vacuum Plate Po-
sition
(1) Use the "Backup Plate Change" tab sheet to set the vacuum plate.
(Operation Sequence: [AUTO OPN.] Button (Main Menu Bar) →
[PRODUCT CHG.] Button (Submenu Bar) → "Backup Plate
Change" Tab Sheet)
Refer to "9.2 "Squeegee Change" Tab" in Section 5 of Chapter 2"
for details.
(2) Select the [JIG Upper End Cam. Move (START)] button and press
the [START] button on the front operation panel.
The P.E.C. recognition camera moves to the upper end face of the
vacuum plate and the upper end face and the cross hairs appear
on the camera monitor.
6.3 "Vac. Plate Pos. Teaching" Tab
0211-005 Chapter 2 6-50 Tg0582-PM-D1

(3) Press the [Eye Adjust] button.
The following window (Fig. 2F39) opens.
Fig. 2F39
The upper end face of the vacuum plate appears on the camera
monitor as shown below.
Perform the manual alignment operation such that the upper end
face of the vacuum plate is aligned with the vertical hair line.
Fig. 2F40
After the end of the manual alignment operation, press the [CLOSE]
button.
The window (Fig. 2F38) resumes.
6.3 "Vac. Plate Pos. Teaching" Tab
0211-005 Chapter 2 6-51 Tg0582-PM-D1

(4) Select the [JIG Lower End Cam. Move (START)] button and press
the [START] button on the front operation panel.
The P.E.C. recognition camera moves to the lower end face of the
vacuum plate and the lower end face and the cross hairs appear
on the camera monitor.
Perform the manual alignment operation such that the lower end
face of the vacuum plate is aligned with the vertical hair line.
(5) Press the [Data Save] button.
The results of the teaching operation is saved and reflected on the
text box of "Vacuum Plate" (Offset Data).
When "Backup Pin" or "Backup Jig" is set in the text box of
"Chuck Stage Select" in the "PCB Backup" tab sheet (Op-
eration Data), be sure to set "0 (zero)" in the text box of
"Vac. Plate Offset".
(6) Select the [Unit Return Execute (START)] button and press the
[START] button on the front operation panel.
The original condition resumes.
6.3.2 Jig Position Offset Correction Function
The correct positional relation between the P.C.B. and the jig (at P.C.B.
positioning) can easily be obtained by setting the jig position offset on
the X/Y table and making the offset teaching possible. (X direction only)
Fig. 2F41
• The offset data of the vacuum plate position is set through teaching
operation such that the centers of the vacuum plate and the P.C.B. in
the X direction overlap each other after the positions (coordinates)
of both ends of the vacuum plate in the X direction are read.
6.3 "Vac. Plate Pos. Teaching" Tab
0211-005 Chapter 2 6-52 Tg0582-PM-D1