1OM-1086-002.pdf - 第164页

Fig. 2C2 • • • • • Using the Other Jigs Consult our marketing department or sales agency for de- tails. Step 3 P .E.C. T est Perform the P .E.C. recognition test for the P .C.B. to be produced, using the "P .E.C. Re…

100%1 / 355
2.2 Model Change Operation
Step 1 Program Change Operation
Set the current pattern program, using the "PROGRAM
CHANGE" window (submenu).
Refer to "7. "PROGRAM CHANGE" Submenu in Sec-
tion 5" for the detailed information on how to perform
the program change operation.
Step 2 Product Change Operation
Perform the various kinds of product change operations, using
the "PRODUCT CHANGE" window (submenu).
Refer to "9. "PRODUCT CHANGE" Submenu in Sec-
tion 5" for the detailed information on how to perform
the product change operation.
(1) Adjustment of Magnet Support Pins and Attachment of
P.C.B. Backup Jig or Holding Jig
Adjust the position of the magnet support pins and attach
the P.C.B. backup jig or the P.C.B. holding jig prepared for
the model to be produced.
• Using the Magnet Support Pins
Consider the arrangement (balance) and insert them at the
points where they can support the P.C.B. securely during
printing and they should not get in the way of printing.
(a) When the magnet support pins are arranged
out of the P.C.B. position or in an unbalanced
condition, printing may not be performed cor-
rectly.
(b) When the magnet support pins are inserted,
using a template, refer to "3.1 Usage of Tem-
plate" for details.
• Using the P.C.B. Backup and Holding Jigs
Align the P.C.B. backup jig with the holes (dimensional po-
sitions) of the backup table and insert the positioning pins.
0211-005
Chapter 2 3-4 Tg0582-PM-D1
2.2 Model Change Operation
Fig. 2C2
••
••
• Using the Other Jigs
Consult our marketing department or sales agency for de-
tails.
Step 3 P.E.C. Test
Perform the P.E.C. recognition test for the P.C.B. to be produced,
using the "P.E.C. Recog. Test" tab sheet. (Operation Sequence:
"MAINT." Window (Main Menu) → "DEVICE TEST" Window
(Submenu) → "P.E.C. Recog. Test" Tab Sheet)
Refer to "7.1 "P.E.C. Recog. Test" Tab" (Section 6 of
Chapter 2) for details.
Step 4 Dual-Camera Auto Calibration
Correct the minute positional deviations of the P.E.C. and screen
recognition cameras, using the "2Cam. Auto Calibration" tab
sheet. (Operation Sequence: "AUTO OPN." Window (Main
Menu) → "PRODUCT CHG." Window (Submenu) → "2Cam.
Auto Calibration" Tab Sheet)
Refer to "9.8 "2 Camera Auto Calibration" Tab" (Section
5 of Chapter 2) for details.
Pick-Up Hole
Backup Jig
Holding Jig
Backup Table
Positioning Pins
0211-005 Chapter 2 3-5 Tg0582-PM-D1
2.2 Model Change Operation
Step 5 Attachment of Squeegees
Attach the squeegees prepared for the model to be produced.
(1) Select the [Squeegee Chg. Pos. Move (START) ] button in
the "Squeegee Chg." tab sheet. (Operation Sequence: [AUTO
OPN.] Button (Main Menu) → [PRODUCT CHG.] Button
(Submenu) → "Squeegee Chg." Tab Sheet)
Refer to "9.2 "Squeegee Change" Tab" (Section 5
of Chapter 2) for details.
(2) Press the [START] button on the front operation panel to
move the squeegee heads forward (toward you).
(3) Set the [OPERATION/SET UP] switch on the front opera-
tion panel to the "SET UP" side.
(4) Open the front safety cover.
(5) Push down the mechanical valve switch (for squeegee fixa-
tion) to the left side (unclamping condition) and insert the
squeegee into the center hole of the squeegee holder.
It is a little bit hard to find the center hole of the
squeegee. To confirm the center hole of the squee-
gee holder, sit down and look up to find the hole.
Fig. 2C3
Squeegee Mechanical Valve Switch for
Squeegee Fixation
0211-005 Chapter 2 3-6 Tg0582-PM-D1
2.2 Model Change Operation