1OM-1086-002.pdf - 第306页

6.3 "V ac. Plate Pos. T eaching" T ab This section enables the operator to perform a teaching operation on the vacuum plate of fset data in the offset data (DA T A EDIT), using the recognition camera and the va…

100%1 / 355
6.2.3 Manual Alignment Operation
When the [Eye Adjust] button is pressed in the "Coordinate Teaching"
tab sheet, the following tab sheet (Fig. 2F37) opens.
Fig. 2F37
[DIRECTION]
• Select the [ ▲ ], [ ▼ ], [
], or [ ] button to specify the direction of
the camera X and Y movement.
The indicated triangle marks show those of an image move-
ment on the camera monitor.
Note the direction of the actual camera unit movement be-
cause the unit moves in the reverse direction of the desig-
nated one.
[SPEED]
• The speed of the camera X and Y movement can be specified.
[HIGH] : Cameras X and Y move at high speed while the
[START] button is being pressed.
[LOW] : Cameras X and Y move at low speed while the
[START] button is being pressed.
[1 PULSE] : Cameras X and Y move in increments of 1 pulse
(0.01 mm) every time the [START] button is
pressed.
0211-005 Chapter 2 6-48 Tg0582-PM-D1
6.2 "Coordinate Teaching" Tab
6.3 "Vac. Plate Pos. Teaching" Tab
This section enables the operator to perform a teaching operation on
the vacuum plate offset data in the offset data (DATA EDIT), using the
recognition camera and the vacuum plate.
The taught data is reflected as the parameter in the "Vacuum Plate" text
box in the "Machine Offset" tab sheet. (Operation Sequence: [SYS-
TEM] Button → [OFFSET DATA] Button → "Machie Offset" Tab Sheet)
••
••
• Sheet Layout
When the [Vac. Plate Pos. Teaching] tab is pressed in the "TEACH-
ING" window (submenu), the following tab sheet (Fig. 2F38) opens.
Fig. 2F38
••
••
• Sheet Composition
*1 "Vac. Plate Offset"
The text box shows the currently specified vacuum plate offset data.
6.3 "Vac. Plate Pos. Teaching" Tab
Do not change the parameter unless necessary. This
parameter is factory-specified upon shipment of the
machine.
CAUTION
*5
*1
*2
*3
*4
0211-005 Chapter 2 6-49 Tg0582-PM-D1
*2 "Operating Unit Selection Button"
[JIG Upper End Cam. Move (START)] Button
When this button is selected and the [START] button on the front
operation panel is pressed with the status indicator showing "ON
(Operation Possible)", the P.E.C. recognition camera starts mov-
ing and the upper end face of the vacuum plate appears in the
"Recognized Image" window.
[JIG Lower End Cam. Move (START)] Button
When this button is selected and the [START] button on the front
operation panel is pressed with the status indicator showing "ON
(Operation Possible)", the P.E.C. recognition camera starts mov-
ing and the lower end face of the vacuum plate appears in the
"Recognized Image" window.
*3 [Eye Adjust] Button
When this button is pressed, the "Camera X Move Opn. Scrn."
window opens.
*4 [Unit Return Execute (START)] Button
When this button is selected and the [START] button on the front
operation panel is pressed with the status indicator showing "ON
(Operation Possible)", each unit is zeroed.
6.3.1 Procedure for Teaching Operation on Vacuum Plate Po-
sition
(1) Use the "Backup Plate Change" tab sheet to set the vacuum plate.
(Operation Sequence: [AUTO OPN.] Button (Main Menu Bar) →
[PRODUCT CHG.] Button (Submenu Bar) → "Backup Plate
Change" Tab Sheet)
Refer to "9.2 "Squeegee Change" Tab" in Section 5 of Chapter 2"
for details.
(2) Select the [JIG Upper End Cam. Move (START)] button and press
the [START] button on the front operation panel.
The P.E.C. recognition camera moves to the upper end face of the
vacuum plate and the upper end face and the cross hairs appear
on the camera monitor.
6.3 "Vac. Plate Pos. Teaching" Tab
0211-005 Chapter 2 6-50 Tg0582-PM-D1