1OM-1086-002.pdf - 第166页
(6) Push down the mechanical valve switch to the right with the squeegee being pushed tightly against the underside of the squeegee holder to fasten the squeegee securely . (a ) Hold the squeegee securely by hand and at-…

Step 5 Attachment of Squeegees
Attach the squeegees prepared for the model to be produced.
(1) Select the [Squeegee Chg. Pos. Move (START) ] button in
the "Squeegee Chg." tab sheet. (Operation Sequence: [AUTO
OPN.] Button (Main Menu) → [PRODUCT CHG.] Button
(Submenu) → "Squeegee Chg." Tab Sheet)
Refer to "9.2 "Squeegee Change" Tab" (Section 5
of Chapter 2) for details.
(2) Press the [START] button on the front operation panel to
move the squeegee heads forward (toward you).
(3) Set the [OPERATION/SET UP] switch on the front opera-
tion panel to the "SET UP" side.
(4) Open the front safety cover.
(5) Push down the mechanical valve switch (for squeegee fixa-
tion) to the left side (unclamping condition) and insert the
squeegee into the center hole of the squeegee holder.
It is a little bit hard to find the center hole of the
squeegee. To confirm the center hole of the squee-
gee holder, sit down and look up to find the hole.
Fig. 2C3
Squeegee Mechanical Valve Switch for
Squeegee Fixation
0211-005 Chapter 2 3-6 Tg0582-PM-D1
2.2 Model Change Operation

(6) Push down the mechanical valve switch to the right with the
squeegee being pushed tightly against the underside of the
squeegee holder to fasten the squeegee securely.
(a) Hold the squeegee securely by hand and at-
tach it.
If the squeegee falls down on the screen, the
screen may be damaged.
It is recommended to place the screen protect-
ing plate on the screen.
(b) The squeegee should be clamped from the rear
side of the holder and then from the front side.
(c) To detach the squeegee, follow the reverse or-
der of (b) and pull down the squeegee.
Fig. 2C3-1
0211-005 Chapter 2 3-7 Tg0582-PM-D1
2.2 Model Change Operation
Screen Protecting Plate

Step 6 Attachment of Screen
Attach the screen prepared for the model to be produced.
Changing the Screen Frame Size
The machine can employ the screen frames with the following
dimensions (4 types).
650 × 550 (Extended Width), 600 × 550 (Extended Width),
550 × 650 (Extended Length), 550 × 550
When the P.C.B. size is "550 × 650 (Extended Length)",
the transfer reference is "Front", and the plate refer-
ence is "Center", printing cannot be made on a P.C.B.
whose width (Y direction) is 100 mm or less.
(1) Open the "Screen Clng." tab sheet (Operation Sequence:
"AUTO OPN." Window (Main Menu) → "PRODUCT CHG."
Window (Submenu) → "Screen Clng." Tab Sheet) and se-
lect the [Scr. Hand Clng. Pos. Move (START) ] button.
Refer to "9.1 "Screen Cleaning" Tab" (Section 5 of
Chapter 2) for details.
(2) Press the [START] button on the front operation panel and
move the screen frame forward (toward you).
(3) Set the [OPERATION/SET UP] switch on the front opera-
tion panel to the "SET UP" side.
Open the front safety door.
(4) Push down the mechanical valve switch (for screen frame
fixation) in the arrow direction to release the cylinders for
screen frame fixation.
Fig. 2C4
0211-005 Chapter 2 3-8 Tg0582-PM-D1
2.2 Model Change Operation