1OM-1086-002.pdf - 第284页
5.3 "T able-Z" T ab This tab sheet can be used to perform the manual alignment operation for the Z axis of the table. • Sheet Layout When the [T able-Z] tab is pressed in the "MANUAL ALIGNMENT" window…

5.2 "Table-X" Tab
This tab sheet can be used to perform the manual alignment operation
for the X axis of the table.
• Sheet Layout
When the [Table-X] tab is pressed in the "MANUAL ALIGNMENT"
window (submenu), the following tab sheet appears.
Fig. 2F18 "Table-X" Tab Sheet
• Sheet Composition
*1 Location
Displayed are the moving distance and the number of pulses that
represent the current location of the unit.
In the case of "Table-X Axis", one pulse is equivalent to "0.01 mm".
Refer to "5.1 Basic Operations of Manual Alignment" for the manual
alignment procedure.
5.2 "Table-X" Tab
*1
0211-005 Chapter 2 6-26 Tg0582-PM-D1

5.3 "Table-Z" Tab
This tab sheet can be used to perform the manual alignment operation
for the Z axis of the table.
• Sheet Layout
When the [Table-Z] tab is pressed in the "MANUAL ALIGNMENT"
window (submenu), the following tab sheet appears.
Fig. 2F19 "Table-Z" Tab Sheet
• Sheet Composition
*1 Location
Displayed are the moving distance and the number of pulses that
represent the current location of the unit.
In the case of "Table-Z Axis", one pulse is equivalent to "0.0065
mm".
Refer to "5.1 Basic Operations of Manual Alignment" for the manual
alignment procedure.
5.3 "Table-Z" Tab
*1
0211-005 Chapter 2 6-27 Tg0582-PM-D1

5.4 "Table- θ " Tab
*1
0211-005 Chapter 2 6-28 Tg0582-PM-D1
5.4 "Table-
θθ
θθ
θ" Tab
This tab sheet can be used to perform the manual alignment operation
for the θ axis of the table.
• Sheet Layout
When the [Table-θ] tab is pressed in the "MANUAL ALIGNMENT"
window (submenu), the following tab sheet appears.
Fig. 2F20 "Table-
θθ
θθ
θ" Tab Sheet
• Sheet Composition
*1 Location
Displayed are the moving distance and the number of pulses that
represent the current location of the unit.
In the case of "Table-θ Axis", one pulse is equivalent to "0.007
mm".
Refer to "5.1 Basic Operations of Manual Alignment" for the manual
alignment procedure.