1OM-1086-002.pdf - 第111页

1.4 Stop and Re-Start Procedures of Automatic Operation 021 1-005 Chapter 1 3 - 21 Tg0582-PM-D1 1.4.2 Stop Operation with the [ST OP] Button Stop Operation • Press the [STOP] button on the front operation panel. The mach…

100%1 / 355
1.4 Stop and Re-Start Procedures of Automatic Operation
0211-005 Chapter 1 3-20 Tg0582-PM-D1
• To replenish components intentionally or during automatic op-
eration
(1) Press the [STOP] button on the front operation panel to stop the
machine temporarily.
(2) Press the [PRODUCT CHG.] button in the "AUTO OPN." window
(submenu) and select the [Squeegee Change] tab.
Fig. 1C32
(3) When the [Paste Scrap. Pos. Move (START)] button is selected
and the [START] button on the front operation panel is pressed,
the squeegee and the screen move to the paste scraping position.
(4) Set the [OPERATION/SET UP] switch on the front operation panel
to "SET UP".
(5) Open the front safety door and supply solder paste additionally to
the paste remaining on the screen.
The solder paste may be found at the rear side, depend-
ing upon the condition in which the machine is stopped.
(7) Close the front safety door.
(8) Set the [OPERATION/SET UP] switch on the front operation panel
to "OPERATION".
(9) When the [START] button on the front operation panel is pressed,
the automatic operation re-starts.
1.4 Stop and Re-Start Procedures of Automatic Operation
0211-005 Chapter 1 3-21 Tg0582-PM-D1
1.4.2 Stop Operation with the [STOP] Button
Stop Operation
• Press the [STOP] button on the front operation panel.
The machine prints solder paste on the P.C.B.’s loaded on the ma-
chine, each device returns to its stationary position, and the machine
stops running.
Re-Start Operation
• Press the [START] button on the operation panel. The machine re-
starts the automatic operation.
Once each device is zeroed, the automatic operation can be
started anytime with each device not located at its origin until
the power of the machine is shut off.
1.4.3 Stop Operation by Selection of "Auto Stop Setting" Tab
When the "Auto Stop Setting" tab is selected and parameters are set
for "Squeegee Limit Stop Setting", the machine stops automatically af-
ter the value has reached the specified one in the text box.
Refer to "Section 5 Menus for Automatic Operation in Chapter 2" for
details.
The machine also stops running automatically under the con-
dition specified using the "Auto Stop" tab sheet in the "Pattern
Program" edit window.
0211-005 Chapter 1 3-22 Tg0582-PM-D1
1.5 Interruption of Automatic Operation
1.5 Interruption of Automatic Operation
1.5.1 Interruption with [EMERGENCY STOP] Switch
To stop the machine immediately in an emergency, press one of the
[EMERGENCY STOP] switches.
Stop Operation
• Press one of the [EMERGENCY STOP] switches.
An alarm is issued and the LED of the [POWER ON] button illumi-
nates in red.
Re-Start Operation
• Refer to the error display on the touch screen and remove the cause
of the error. Then, press the [RESET] button.
Refer to "Section 4 Remedy of Simple Trouble in Chapter 1" for the
detailed information on how to reset the machine from the emer-
gency stop condition to its normal one.