9. 6 "Conveyor Width" T ab This tab sheet enables the operator to change the conveyor width to the target value and perform the inching operation. • Sheet Layout When the [Conveyor Wd.] tab is pressed in the &q…

(a) When the up arrow to the right of a text box is pressed,
the numerical value increases by 1. Pressing the down
arrow decreases it by 1.
(b) When the "Scraping Count" test box (background
color: cream) is pressed, a ten-key window opens.
The number of kneading times can be entered di-
rectly, using this ten-key window.
Fig. 2E31
*2 [Paste Scraping (START)] Button
When this button is pressed, the background color turns blue.
When the [START] button on the front operation panel is pressed
subsequently, the paste kneading operation starts to level the sol-
der paste.
*3 Message
A message is issued, giving a guideline of the operations.
(a) When the [STOP] button on the front operation panel
is pressed during paste kneading, the kneading ac-
tion stops.
(b) It takes a little time until the kneading stops after the
[STOP] button is pressed.
9.5 "Paste Scraping" Tab
0211-005 Chapter 2 5-44 Tg0582-PM-D1

9.6 "Conveyor Width" Tab
This tab sheet enables the operator to change the conveyor width to
the target value and perform the inching operation.
• Sheet Layout
When the [Conveyor Wd.] tab is pressed in the "PRODUCT
CHANGE" window (submenu), the following tab sheet appears.
Fig. 2E32 "Conveyor Width" Tab Sheet
• Sheet Composition
*1 Conveyor Select Buttons
Select one of the buttons to specify the conveyor whose width should
be changed such that a P.C.B. can pass smoothly through it.
When one of the buttons ([L Cnvr. Wd.], [Chute Wd.], and [R Cnvr.
Wd.] buttons) is pressed, it turns blue, indicating that it is selected.
*2 P.C.B. Size Y
Displayed are the dimension (Y direction) of the P.C.B. and the
current width (Y direction) of the conveyor selected in the above-
described *1.
*3 Target Wd.
Enter a value as the target width (Y direction) of the conveyor se-
lected in the above-described *1.
9.6 "Conveyor Width" Tab
*1
*8
*6
*2
*7
*9
*3
*5
*4
0211-005 Chapter 2 5-45 Tg0582-PM-D1

When the "Target Wd." text box (background color: cream)
is pressed, a ten-key window opens.
Enter the target dimension, using the ten-key window.
Fig. 2E33
*4 Status
The current state related to the target value in the "Target Wd."
text box *3 is displayed.
DONE
::
::
: This indicates that the width adjustment is com-
pleted because the target value (target width (Y
direction) of the conveyor selected in the above-
described "*1") has matched the current width.
MOVING
::
::
: This indicates that the conveyor is moving until the
width reaches its target value.
NOT RDY
::
::
: This indicates that the target value specified be-
fore the power is turned off matched the actual con-
veyor width but the current conveyor width is not
confirmed.
- - - (Background Color: White):
This indicates that the production model is not
specified or the target value has not matched the
actual conveyor width.
*5 Clearance
This enables the operator to reset the difference between the width
of the P.C.B. and the widths of the L/R and table chute conveyors.
When the "Clearance" text box (background color: cream)
is pressed, a ten-key window opens.
Enter the clearance (dimension), using the ten-key win-
dow and press the [Clearance Reset] button *6.
Fig. 2E34
9.6 "Conveyor Width" Tab