Movement to Assigned Position Select the [Assign. Posn. Move (ST ART)] button for "Fiducial Mark #2" (Second Screen Recognition Mark). • Press the "X" or the "Y" data box under "Recog. …

100%1 / 355
7.2.3 Camera Movement Operation
Select the [Camera X-Y Move] button.
The "Screen Recog. Camera Move Opn. Scrn." window (Fig. 2F58)
opens.
Fig. 2F58
Manual Alignment Operation
Select the [Eye Adjust (START)] button for "Fiducial Mark #1" (First
Screen Recognition Mark).
• Specify the direction with the [ ], the [ ], the [ ], or the [ ] button.
• Specify the speed with the [HIGH], the [LOW], or the [1 PULSE]
button.
• Press the [START] button on the front operation panel and move the
screen recognition mark to the position in the recognition area where
the mark should be recognized.
While the [START] button on the front operation panel is being
pressed, the camera keeps on moving.
• Press the [CLOSE] button. The tab sheet (Fig. 2F54) resumes.
7.2
"
Screen Recog. Test
"
Tab
0211-005 Chapter 2 6-70 Tg0582-PM-D1
Movement to Assigned Position
Select the [Assign. Posn. Move (START)] button for "Fiducial Mark #2"
(Second Screen Recognition Mark).
• Press the "X" or the "Y" data box under "Recog. Camera Move Posn.
Assign.". A ten-key window appears. Enter a value, using the panel.
Press the [AC] button whenever it is necessary to clear the data.
With the [#1 Pos.] or [#2 Pos.] buttons, the designated coor-
dinates in the pattern program can be copied in the "Recog.
Camera Move Posn. Assign." data boxes.
• When the [START] button on the front operation panel is pressed,
the screen recognition camera moves to the assigned position.
• Press the [Eye Adjust (START)] button to perform the same opera-
tion as "Manual Alignment" and move the screen recognition mark
to the position where the mark should be recognized.
7.2
"
Screen Recog. Test
"
Tab
0211-005 Chapter 2 6-71 Tg0582-PM-D1
Fig. 2F58-1
7.2.4 Camera Monitor
When the "Screen Recog. Test" tab sheet becomes active, a recogni-
tion area appears on the camera monitor.
When the setting of the recognition area is changed, the display
area also changes.
Fig. 2F59
• When the recognition is made normally, the camera moves, the im-
age of the screen recognition mark moves to the camera center, and
the outline of the mark shape and the cross hairs appear in the win-
dow (recognition area).
The positional deviation (X and Y) of the screen recognition mark
from the camera center is displayed in the "A"-marked area of the
window.
The displayed positional deviation shows the deviation de-
tected before testing.
Fig. 2F60
The point of the cross hairs intersection is the camera center.
• When the results of the recognition is "NG (No Good)", the outline of
the mark shape and the cross hairs do not appear and an error mes-
sage (recognition error) is issued on the touch screen.
7.2
"
Screen Recog. Test
"
Tab