7 Repairs to SmartFeeder 8 mm X 7.14 Handle with control panel 126 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 7.14.2.1 Removing other spare parts ► Carefully place the feeder module with the right side down …

7 Repairs to SmartFeeder 8 mm X
7.14 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 125
7.14.2 Other spare parts on the handle
Required spare parts
Fig.39: Spare parts for handle SmartFeeder 8 mm X
Feeder module Position Item no. Designation
SmartFeeder 8mmX 1 03108403Sxx Slide for foil stuffing unit assy. X8Smart
2 03009150Sxx Pressure spring VD-090V
3 03113828Sxx Spring hook for slide X8Smart
4 03033796-xx RF-SN75-2.5 x 6-9.8
5 03101437Sxx Window for operating panel X8Smart
6 03101508Sxx Cover for foil stuffing unit X8Smart
Required tools
●
Phillips screwdriver 0.9Nm
●
TORX screwdriver 0.6Nm, size T8
●
Tweezers or flat pliers

7 Repairs to SmartFeeder 8 mm X
7.14 Handle with control panel
126 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
7.14.2.1 Removing other spare parts
► Carefully place the feeder module with the right side down on a stable, level and clean sur-
face.
► Remove the left side cover (see 7.3.1 "Removing the Left Side Cover" [}83]).
► Remove the operating panel (see 7.14.1.1 "Removing the Control Panel and Board" [}122]).
If you have removed the operating panel, the cover on the foil stuffing unit will be accessible and
can be replaced if necessary.
► Pull the slide up and out of the handle. (1)
► Remove the pressure spring. (2)
► Remove the screw which fastens the spring
hook(1) to the handle.
► Remove the spring hook.
7.14.2.2 Fitting other spare parts
► Hold the spring hook as shown(1) by the handle,
so that you can look through the opening and see
the hole for the screw.
► Screw the spring hook to the handle. Use a size
T8 TORX screwdriver with 0.6 Nm for this.

7 Repairs to SmartFeeder 8 mm X
7.14 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 127
► Push one end of the pressure spring in the
handle, as shown.(1)
► Insert the slide into the other end of the pressure
spring.(2)
► Press the slide into the pressure spring and insert
it from above, into the handle.(3)
At this point, the cover on the foil stuffing unit will be accessible and can be replaced if necessary,
before you fit the operating panel.
► Fasten the operating panel (see 7.14.1.2 "Fitting the Control Panel and Board" [}123]).
► Fasten the left side cover (see 7.3.2 "Fitting the left side cover" [}83]).