00198505-01_SM_SIPLACE_SmartFeeder_EN.pdf - 第67页
6 Repairs to SmartFeeder 4 mm X 6.12 Flap/drip tray for cover foil Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 67 6.12.1 Replacing the drip tray and shaft ► Carefully place the feeder module with the left sid…

6 Repairs to SmartFeeder 4 mm X
6.12 Flap/drip tray for cover foil
66 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
6.12 Flap/drip tray for cover foil
Required spare part
Fig.16: Drip tray and shaft
Feeder module Position Item no. Designation
SmartFeeder 4mmX 1 03119392Sxx Drip tray for cover foil X4Smart
2 03004081-xx Shaft for D2 foil flap X8
Required tools
●
TORX screwdriver size T8, with 0.6Nm
●
Phillips screwdriver 0.9Nm

6 Repairs to SmartFeeder 4 mm X
6.12 Flap/drip tray for cover foil
Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 67
6.12.1 Replacing the drip tray and shaft
► Carefully place the feeder module with the left side down on a stable, level and clean surface.
► Remove the right side cover (see 6.3.3 "Removing the Right Side Cover" [}32])
► Remove the "insertion foil container" (see 6.14.1 "Replacing the foil container" [}69]).
► Clean the foil container thoroughly and remove all foil and adhesive residues.
► Remove the "cover foil drip tray"(1) and, if
needed, the "shaft D2"(2). The shaft is just inser-
ted into the foil container.
► Insert the (new) "shaft D2"(1) in the position
shown in the foil container, as far as the stop.
► Push the (new) cover foil drip tray onto the "shaft
D2".
► Fit the "insertion foil container" (see 6.14.1 "Replacing the foil container" [}69]).
► Fit the right side cover (see6.3.4 "Fitting the Right Side Cover" [}33]).

6 Repairs to SmartFeeder 4 mm X
6.13 Foil disposal blade
68 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
6.13 Foil disposal blade
Required spare part
Fig.17: Blade partition wall
Feeder module Item no. Designation
SmartFeeder 4mmX 00341370Sxx Blade partition wall
NOTICE
Pay attention when preparing the individual blades. Individual blades must be broken at the
cutter edge. Ensure all safety precautions are observed.
Required tools
●
TORX screwdriver 0.6Nm, size T8
WARNING
Risk of injury
The edge of the blade is very sharp. Make sure that you always use a pair of tweezers
when removing and fitting the blade.
6.13.1 Removing the Blade Partition Wall
► Place the feeder on a stable, level and clean surface.
► Open the flap.
► Loosen the screw fastening the blade and remove the old blade.
6.13.2 Fitting the Blade Partition Wall
► Place the new blade in position and tighten the screw.
CAUTION
► The blades are sharp, take necessary safety precautions.