8 Repairs to SmartFeeder 2x8 mm X 8.6 Splice sensor / dummy Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 145 ► Fix the splice sensor to the lane with the screws provided. ► Fit the second splice sensor in the …

8 Repairs to SmartFeeder 2x8 mm X
8.6 Splice sensor / dummy
144 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
8.6.2 Fitting the splice sensor
NOTICE
Always fit both splice sensors.
If you want to use splice sensors for the feeder module, both lanes need to be supplied with
splice sensors.
When you connect the splice sensors, make sure that you use the right cable for the lane in
each case:
- The cable for the splice sensor on the left lane has the colors red, white and black.
- The cable for the splice sensor on the right lane has the colors red, brown and black.
► Pull the sensor cable for that lane out of the cable
duct.
► Plug the connector for the sensor cable into the
connection on the splice sensor.
► Carefully guide the sensor cable back into the
cable duct.
► Place the splice sensor onto the lane.
Make sure that you do not pinch the cable but
that it is fed into the cable duct properly.
► Push the splice sensorin the direction of the ar-
row, as far as the stop, towards the tape duct.
Make sure that the nib at the front of the splice
sensor is completely inserted into the tape duct.

8 Repairs to SmartFeeder 2x8 mm X
8.6 Splice sensor / dummy
Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017 145
► Fix the splice sensor to the lane with the screws
provided.
► Fit the second splice sensor in the other lane.
The procedure is the same as that for the first
splice sensor.
After installation, the splice sensors will be automatic-
ally recognized and do not require any additional activ-
ation.
8.6.3 Removing the splice sensor
► Remove the screw fastening the splice sensor to
the lane.

8 Repairs to SmartFeeder 2x8 mm X
8.6 Splice sensor / dummy
146 Service Manual SIPLACE SmartFeeder 4 - 104 mm X 11/2017
► Pull the splice sensor out of the tape duct, in the
direction of the arrow.
► Lift the splice sensor out of the lane.
Make sure that you do not stretch the cable too
much.
► Pull the connector for the sensor cable out of the
connection on the splice sensor.
► Remove the splice sensor.
► Insert the sensor cable back into the cable duct.
If you want to use a dummy splice sensor, remove the
second splice sensor. The procedure is the same as
that for the first splice sensor.