5 Using the SMA SMA Guide SIPLACE Explorer Edition 11/2020 EN from 3.11 (R20-2) 102 5.10 Defining Quality Factor In SIPLACE Explorer there are two possib ilities to apply a qual ity factor: 5 – Defining the quality facto…

SMA Guide SIPLACE Explorer 5 Using the SMA
from 3.11 (R20-2) Edition 11/2020 EN
101
5.9 View Further Details by Using the Tracks with the Most Pickup
Errors as an Example
Select the Pickup Reliability website.
Select and click on the required track from the example using the tracks with the most pickup
errors. The view will change as shown below:
5
Fig. 5 - 9 Pickup reliability
Select a display criterion for the pareto diagram from the Drill Down list. This example shows
by Component.
The pareto diagram will be adjusted accordingly. The component reject quantity for the
selected track will be shown as a percentage.
Click on the Back icon to return to an overview of all tracks.
NOTE
If data is recorded during the machine status "stand-alone", this data will not be taken into account
in the detailed views of the diagrams Worst Components and Worst Package Forms, although
it is shown in the diagram Worst Tracks. 5

5 Using the SMA SMA Guide SIPLACE Explorer
Edition 11/2020 EN from 3.11 (R20-2)
102
5.10 Defining Quality Factor
In SIPLACE Explorer there are two possibilities to apply a quality factor: 5
– Defining the quality factor in SIPLACE Explorer manually
– Importing the quality factor to SIPLACE Explorer from an xml file
5.10.1 How to define a quality factor in SIPLACE Explorer
Select the OLE/OEE Summary website.
Click on the Set quality factor button. The Set Quality Factor dialog box will open:
5
Fig. 5 - 10 Set quality factor
Use the calendar to select an evaluation period.
In the Quality Factor field, specify the target quality value which is to be reached during the
evaluation period.
Check your entries and confirm with OK.
This quality factor will be shown as a line in the Display OLE/OEE diagram.

SMA Guide SIPLACE Explorer 5 Using the SMA
from 3.11 (R20-2) Edition 11/2020 EN
103
5.10.2 How to import a quality factor from an xml file
A quality factor can be imported to SIPLACE Explorer from an xml file. 5
Destination folder of the xml file:
<SIPLACE Explorer root>\OEE, e.g. C:\SIPLACE Explorer\OEE 5
Naming convention for the xml file:
<LineName>_<dateBegin>_<dateEnd>.xml, e.g. Line_1_06052819_06052820.xml 5
Contents of the xml file:
5
Fig. 5 - 11 Set quality factor
– Line name
– Begin of the evaluation period
– End of the evaluation period
– Quality factor
Note
You can find an xml file for example on the product CD in the ...\Documentation folder. 5
5.11 Defining Target Value
On the OEE Analysis page target values can be defined for each machine in the production line
or for the entire production line. 5
NOTE