5 Using the SMA SMA Guide SIPLACE Explorer Edition 11/2020 EN from 3.11 (R20-2) 96 5.3 How to Sort T ables Open the required line webs ite an d select any p age. The table can be s orted by a ny column (d escending o…
SMA Guide SIPLACE Explorer 5 Using the SMA
from 3.11 (R20-2) Edition 11/2020 EN
95
Table 5
The table shows the components in ascending order of consumption. The component with the
lowest consumption is displayed in the first line of the table. 5
The table has the following columns: 5
– Component
Component name
– Placed
Number of components placed.
– Consumed
Total from placed + reject vacuum + reject ident.
–Wasted
Number of components that are not used.
–Pickup Error
– Number of component rejects caused by pickup errors.
– Ident
Number of component rejects caused by ident. errors.
–MD
Number of coplan or material errors detected by the vision system.
– Process Error
Number of process errors that occurred.
The table has the following rows (lines): 5
– One line of consumption data for each component
– Page Total:
Shows the total amount for the columns Placed, Consumed, Vacuum, Ident. This total amount
will be calculated for each page and shown at the bottom of the page.
– Query Total:
Shows the total amount for each column, on all pages. This line is displayed at the end of each
page.

5 Using the SMA SMA Guide SIPLACE Explorer
Edition 11/2020 EN from 3.11 (R20-2)
96
5.3 How to Sort Tables
Open the required line website and select any page.
The table can be sorted by any column (descending or ascending order). Simply click on the
header line of the required column.
An arrow in the column header indicates by which column the contents have been sorted.
5.4 How to Enable Legends
Open the required line website and select any page.
It is possible to select/deselect the states that are illustrated in the bar chart. 5
De-selection of State will result in redraw of the chart without the State. This is useful if only a
one or a combination of States is desired in the view. As an example - it is possible to display
only "Scheduled Down & Unscheduled Down" within a chart. States can be selected
individually in any combination.
Select/Deselect All:
the buttons below the chart allow a one click selection for All/None. 5
5.5 How to Export the Data Shown as an MS Excel File
Open the required line website and select any page.
Click on the icon. Another Internet Explorer window will open, in which the generated MS
Excel file will be shown:

SMA Guide SIPLACE Explorer 5 Using the SMA
from 3.11 (R20-2) Edition 11/2020 EN
97
5
Fig. 5 - 6 MS-Excel-Export
The Excel file shows data of the Pickup Reliability website.
You can save this file or just close the window to return to the previous view.
5.6 Making Logbook Entries
The logbook provides a method to enter notes and causes related to line disruptions or events of
interest. Logbook entries consist of a reason, a start/end time, as well as additional detail notes.
The entry can be in relation to the entire line or a specific machine. Entry is possible via the web
browser if the user has defined rights to allow an entry. 5