00197723-12_UG_SE3.11_EN.pdf - 第80页
4 Functions Overview SMA Guide SIPLACE Explorer Edition 11/2020 EN from 3.11 (R20-2) 80 4 Fig. 4 - 23 T opic: 7_X4_3 - reject rate NOTE If data is r ecorded in the machin e st atus "stan d-alone", a plac eholde…

SMA Guide SIPLACE Explorer 4 Functions Overview
from 3.11 (R20-2) Edition 11/2020 EN
79
– Material Defects:
Number of coplan or material errors detected by the vision system per hour. 4
– Process Error:
Number of process errors that occurred per hour. 4
– Absence before placement
Number of components that have not been not on the head nozzle after component pickup per
hour. 4
– Present after placement
Number of components that are still on the head nozzle after placement per hour. 4
– Treat. error
Number of components that have been rejected during the process step of dipping or gluing
per hour. 4
– Dropped
Number of components that have been rejected after board abortion per hour. 4
NOTE
The current hour may only display a partial bar chart. The data for the current hour is updated as
the hour progresses. At the end of the hour, a complete bar will be shown (Future time is not
shown). 4
4.2.3 Reject Rate
This page gives you a detailed description of the reject rate, divided into the following: 4
– Location at the machine and track on the component table
– Component name
– Component shape
– Number of vacuum and identification errors
Shows the percentage of the total quantity picked up from this track
– Components picked up:
Shows the total number of components picked up from this track.

4 Functions Overview SMA Guide SIPLACE Explorer
Edition 11/2020 EN from 3.11 (R20-2)
80
4
Fig. 4 - 23 Topic: 7_X4_3 - reject rate
NOTE
If data is recorded in the machine status "stand-alone", a placeholder (N/A) will be shown in the
columns Feeder type, Component and CS (component shape). 4
– Reject rate by Feeder Location and Component
Explanation of Table: 4
Consumption and Reject Data for the Evaluation Interval: 4
– Feeder Type:
The Feeder Type (e.g. 12mm, 16mm). 4
–Table:
The Table or Location of the feeder. 4
– Track:
The feeder Track. If from an MTC/WPC "-" is displayed. 4
– Division:
The division for the feeder track or MTC/WPC. 4
SMA Guide SIPLACE Explorer 4 Functions Overview
from 3.11 (R20-2) Edition 11/2020 EN
81
–Tower:
Tower Identity if from MTC, "-" is displayed for a feeder. 4
– Level:
Level Identity if from MTC, "-" is displayed for a feeder. 4
– Component:
Component name. 4
– Consumed:
Total consumed components. 4
– Component Shape:
Component shape of the component. 4
– Placed:
Total placed components. 4
– Wasted:
Number of components that have not been used by the placement. 4
– Pickup Errors [%] / [Count]:
Number of pickup errors that have occurred on the station. 4
– Ident Errors [%] / [Count]:
Number of identity errors that have occurred on the station. 4
– Rejected:
Number of components that have been rejected by the placement station. 4
– Material Defects:
Number of coplan or material errors detected by the vision system. 4
– Process Error:
Number of process errors that occurred. 4
– Absence before placement
Number of components that have not been not on the head nozzle after component pickup.4
– Present after placement
Number of components that are still on the head nozzle after placement. 4