00197723-12_UG_SE3.11_EN.pdf - 第51页
SMA Guide SIPLACE Explorer 4 Functions Overview from 3.11 (R20-2) Edition 11/2020 EN 5 1 NOTE If data is recorded in the machin e st atus "stand-alone", this d ata will not be t aken into account in the diagram…
4 Functions Overview SMA Guide SIPLACE Explorer
Edition 11/2020 EN from 3.11 (R20-2)
50
– % Rejected:
Percentage of rejected components that occurred within the evaluation interval (See
definition of Rejected %). 4
– Pickup Errors:
The sum of pickup errors that occurred within the evaluation interval. 4
– % Pickup Errors:
Percentage of rejected components due to pickup errors that occurred within the evaluation
interval (See definition of Vacuum Error %). 4
– Identification Errors:
The sum of Identification errors that occurred within the evaluation interval. 4
– % Identification Errors:
Percentage of rejected components due to Identification errors that occurred within the
evaluation interval. 4
–MD:
The sum of coplan or material errors detected by the vision system within the evaluation
interval. 4
– Process Errors:
The sum of process errors that occurred within the evaluation interval. 4
– Worst Tracks - Bar Chart
A Bar Chart that shows the tracks for the line with the largest Pickup Error Rate, during the
evaluation interval. Sorted in descending order. 4
– Worst Components - Bar Chart
A Bar Chart that shows the components for the line with the largest Pickup Error Rate, during
the evaluation interval. Sorted in descending order. 4
– Worst Package Forms - Bar Chart
A Bar Chart that shows the package forms for the line with the largest Pickup Error Rate, during
the evaluation interval. Sorted in descending order. The data for each track, component or
component shape shown can also be displayed in more detail. 4

SMA Guide SIPLACE Explorer 4 Functions Overview
from 3.11 (R20-2) Edition 11/2020 EN
51
NOTE
If data is recorded in the machine status "stand-alone", this data will not be taken into account in
the diagrams Worst Components and Worst Package Forms. The diagram Worst Tracks
shows the data as it is when read out of the OIS and also contains data which was recorded in the
machine status "stand-alone". The overview table shows the data as it is read out of the OIS. 4
The following procedures can be performed on this page and are described in this SMA
User Guide:
“View Further Details by Using the Tracks with the Most Pickup Errors as an Example” on
page 101
“How to Specify the Generation of Line Reports” on page 90
“How to Sort Tables” on page 96
“How to Enable Legends” on page 96
4.1.9 Pickup Summary
This page shows you a summary of picked up and rejected components, by line. 4
The information is shown in a pareto diagram. Select the items you wish to view from the drop-
down menu list: 4
– Rejects by track
– Access total by track
– Rejects by component
– Access total by feeder type
– Rejects by feeder type
– Access total by package form
– Rejects by package form
– Pickup errors by error name