00197723-12_UG_SE3.11_EN.pdf - 第84页

4 Functions Overview SMA Guide SIPLACE Explorer Edition 11/2020 EN from 3.11 (R20-2) 84 – Material D efects: Number of coplan or material err ors detected by the vision syst em. 4 – Process Error: Number of process err o…

100%1 / 114
SMA Guide SIPLACE Explorer 4 Functions Overview
from 3.11 (R20-2) Edition 11/2020 EN
83
– Material Defects:
Number of coplan or material errors detected by the vision system. 4
– Process Error:
Number of process errors that occurred. 4
– Absence before placement
Number of components that have not been not on the head nozzle after component
pickup. 4
– Present after placement
Number of components that are still on the head nozzle after placement. 4
– Treat. error
Number of components that have been rejected during the process step of dipping or
gluing. 4
– Dropped
Number of components that have been rejected after board abortion. 4
– Reject rate by Component
Explanation of Table: 4
Consumption and Reject Data for the Evaluation Interval: 4
– Component:
Component Name. 4
– Consumed:
Total consumed components. 4
– Placed:
Total placed components. 4
– Wasted:
Number of components that have not been used by the placement. 4
– Pickup Errors [%] / [Count]:
Number of pickup errors that have occurred on the station. 4
– Ident Errors [%] / [Count]:
Number of identity errors that have occurred on the station. 4
– Rejected:
Number of components that have been rejected by the placement station. 4
4 Functions Overview SMA Guide SIPLACE Explorer
Edition 11/2020 EN from 3.11 (R20-2)
84
– Material Defects:
Number of coplan or material errors detected by the vision system. 4
– Process Error:
Number of process errors that occurred. 4
– Absence before placement
Number of components that have not been not on the head nozzle after component
pickup. 4
– Present after placement
Number of components that are still on the head nozzle after placement. 4
– Treat. error
Number of components that have been rejected during the process step of dipping or
gluing. 4
– Dropped
Number of components that have been rejected after board abortion. 4
– Reject rate by Component Shape
Explanation of Table: 4
Consumption and Reject Data for the Evaluation Interval: 4
– Component Shape:
Component Shape of the Component. 4
–Consumed:
Total consumed components. 4
–Placed:
Total placed components. 4
–Wasted:
Number of components that have not been used by the placement. 4
– Pickup Errors [%] / [Count]:
Number of pickup errors that have occurred on the station. 4
– Ident Errors [%] / [Count]:
Number of identity errors that have occurred on the station. 4
– Rejected:
Number of components that have been rejected by the placement station. 4
SMA Guide SIPLACE Explorer 4 Functions Overview
from 3.11 (R20-2) Edition 11/2020 EN
85
– Material Defects:
Number of coplan or material errors detected by the vision system. 4
– Process Error:
Number of process errors that occurred. 4
– Absence before placement
Number of components that have not been not on the head nozzle after component
pickup. 4
– Present after placement
Number of components that are still on the head nozzle after placement. 4
– Treat. error
Number of components that have been rejected during the process step of dipping or
gluing. 4
– Dropped
Number of components that have been rejected after board abortion. 4
– Definition of Component Sum
Component Sum = (S placed Components + S errors) 4
– Definition of Total Component Rejects
Total Rejects = (S Identification errors + S Vacuum errors) 4
– Definition of Total Rejects %
Rejected % = (S Total Rejects / (S placed Components + S errors)) * 100 4
– Definition of Vacuum Error %
Vacuum Error % = (S vacuum error / (S placed Components + S errors)) * 100 4
– Definition of Identification Error %
Identification Error % = (S identification error / (S placed Components + S errors)) * 100 4
4.2.3.1 Possible discrepancy between SIPLACE Explorer and OIS placement data
The number of consumed components, rejects and boards may differ between SIPLACE Explorer
and OIS. 4
In OIS each data record has a timestamp (consumed components, rejected components and each
board). If an OIS query is sent via SQL Query to OIS, for the consumption quantity within a certain
period, it will return the number of component records which have a timestamp within the specified
period. 4