00197723-12_UG_SE3.11_EN.pdf - 第63页
SMA Guide SIPLACE Explorer 4 Functions Overview from 3.11 (R20-2) Edition 11/2020 EN 6 3 4.2.1.2 E10 St ate by the Hour This page pr ovides a stacked ba r chart vie w , showing ov erall ti me in S tate according to E10 f…

SMA Guide SIPLACE Explorer 4 Functions Overview
from 3.11 (R20-2) Edition 11/2020 EN
63
4.2.1.2 E10 State by the Hour
This page provides a stacked bar chart view, showing overall time in State according to E10 for
each hour within the evaluation interval. Time and date of each hour is shown for the bar label. 4
NOTE
There is a special OIS status module realized in SIPLACE OIS. This OIS status module is shown
in the SIPLACE Explorer status module which matches the SEMI E10 status module. This may
lead to deviations in the states and status times shown between OIS and SIPLACE Explorer. A
direct comparison is therefore not possible. For further details, please refer to the Software
Version Description SIPLACE Explorer. See also “Relationship Between E10 State Summary and
Performance” on page 26. 4
4
Fig. 4 - 16 Topic: 7_X4_3 - E10 state by hour

4 Functions Overview SMA Guide SIPLACE Explorer
Edition 11/2020 EN from 3.11 (R20-2)
64
– Bar Chart Segments
Holding the mouse over a segment of the bar chart will display in a tool tip the value of the
segment. 4
– Scaling Zoom In/Out
By clicking and dragging - it is possible to zoom the scale of the bar chart for viewing of smaller
values. This is especially useful if a large value is displayed elsewhere on the chart and you
wish to view a smaller value. Double clicking near the top of the chart will return the Zoom
Factor to the original. 4
The following procedure can be performed on this page and is described in this SMA User
Guide:
“How to Enable Legends” on page 96
4.2.1.3 Downtime Analysis
4
Fig. 4 - 17 Topic: 7_X4_3 - downtime analysis