8 Repairs to SmartFeeder 2x8 mm X / Xi 8.7 Splice sensor / dummy Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 199 ► Lower the dummy sensor completely down. ► Push the dum…

8 Repairs to SmartFeeder 2x8 mm X / Xi
8.7 Splice sensor / dummy
198 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
8.7.4 Fitting the Dummy Splice Sensor
CAUTION
During assembly, make sure that the cable is not wedged in between the base unit, the
dummy splice sensor and the side covers.
► Place the feeder module down on a stable sur-
face e.g. a single slot EDIF or place the feeder
module on a level and clean surface.
► Place the dummy sensor next to the tape duct, as
shown in the diagram.
► Swing the dummy sensor up with the tip pointing
upwards.
► Pull the cable about 4 cm out of the base unit of
the feeder module.
► Push the cable connector from the outside, side-
ways into the dummy sensor guidance.
Make sure that the cable is pushed into the
dummy sensor on the correct side, as shown.
► Push the cable into each left and right cable duct
in the base unit of the feeder module.
► Carefully swing the dummy sensor down.
Make sure that the cable is not wedged in
between the base unit, the dummy splice sensor
and the side covers.

8 Repairs to SmartFeeder 2x8 mm X / Xi
8.7 Splice sensor / dummy
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 199
► Lower the dummy sensor completely down.
► Push the dummy sensorforwards, in the direction
of the arrow, as far as the stop.
► Fasten the dummy sensor with a screw (M2,
5x6).
Use a Phillips screwdriver for this.

8 Repairs to SmartFeeder 2x8 mm X / Xi
8.7 Splice sensor / dummy
200 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
8.7.5 Cable splice sensor
Spare part required
Fig.61: Cable splice sensor
Feeder module Item no. Designation
SmartFeeder 2x8 mm X
SmartFeeder 2x8 mm Xi
03063593-xx Cable for splice sensor X2x8
Tools required
●
Phillips screwdriver
●
TORX screwdriver size T8
8.7.5.1 Removing the Cable Splice Sensor
► Place the feeder on a stable, level and clean sur-
face.
► Remove the left and right side covers. (See 8.3.1
"Removing the Left Side Cover" [}174], 8.3.3
"Removing the Right Side Cover" [}175])
► Disconnect the connector from the main
board(1)
.
► Remove the seal band left and right(2).
► Remove the M2.5x6 screw from splice sensor(3)
and disconnect the cables(4).