Service Manual SIPLACE SmartFeeder.pdf - 第40页
6 Repairs to SmartFeeder 4 mm X / Xi 6.5 Pickup window 40 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 6.5.3 Removing the actuator ► Remove the pickup window (see 6.5.1 &…

6 Repairs to SmartFeeder 4 mm X / Xi
6.5 Pickup window
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 39
► Press the pickup window slightly upwards and
push it into the prescribed position.
► Carefully place the feeder module with the left
side down on a stable, level and clean surface.
► Insert both pressure springs.
Make sure that the bottom ends of the pressure
springs are not inserted into the groove.
► Insert the nibs of the counterplate into the bottom
ends of the pressure springs.
► Carefully push the counterplate upwards, until
both of the counterplate nibs engage with the
pressure springs in the pickup window.
► Push the counterplate upwards even more, until
the threaded holes of the pickup window are
completely visible in the holes of the counter-
plate.
Make sure that you do not get the counter-
plate(1)
and the actuator(2) jammed against one
another in the marked area.
► Fix the counterplate into place with the two Phil-
lips screws marked.

6 Repairs to SmartFeeder 4 mm X / Xi
6.5 Pickup window
40 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
6.5.3 Removing the actuator
► Remove the pickup window (see6.5.1 "Removing
the Pickup Window" [}37]).
► Remove the sealing element (1) from the fitting
screw hole(2)
.
► Remove the fitting screw shown in the diagram.
(2)
Use a 1.5mm Allen key.
► Pull the actuator on the righthand side of the
feeder module out of the base unit.

6 Repairs to SmartFeeder 4 mm X / Xi
6.5 Pickup window
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 41
6.5.4 Fitting the actuator
► Push the actuator on the righthand side of the
feeder module into the base unit as shown.
During this, push the actuator axis into the hole
shown in the diagram.
► Fasten the actuator axis with a fitting screw(2).
Use a 1.5mm Allen key for this.
► Fit the sealing element (1) onto the fitting screw
hole (2).
► Fasten the pickup window (see 6.5.2 "Fitting the
pickup window" [}38]).