6 Repairs to SmartFeeder 4 mm X / Xi
6.5 Pickup window
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 39
Press the pickup window slightly upwards and
push it into the prescribed position.
Carefully place the feeder module with the left
side down on a stable, level and clean surface.
Insert both pressure springs.
Make sure that the bottom ends of the pressure
springs are not inserted into the groove.
Insert the nibs of the counterplate into the bottom
ends of the pressure springs.
Carefully push the counterplate upwards, until
both of the counterplate nibs engage with the
pressure springs in the pickup window.
Push the counterplate upwards even more, until
the threaded holes of the pickup window are
completely visible in the holes of the counter-
plate.
Make sure that you do not get the counter-
plate(1)
and the actuator(2) jammed against one
another in the marked area.
Fix the counterplate into place with the two Phil-
lips screws marked.
6 Repairs to SmartFeeder 4 mm X / Xi
6.5 Pickup window
40 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
6.5.3 Removing the actuator
Remove the pickup window (see6.5.1 "Removing
the Pickup Window" [}37]).
Remove the sealing element (1) from the fitting
screw hole(2)
.
Remove the fitting screw shown in the diagram.
(2)
Use a 1.5mm Allen key.
Pull the actuator on the righthand side of the
feeder module out of the base unit.
6 Repairs to SmartFeeder 4 mm X / Xi
6.5 Pickup window
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 41
6.5.4 Fitting the actuator
Push the actuator on the righthand side of the
feeder module into the base unit as shown.
During this, push the actuator axis into the hole
shown in the diagram.
Fasten the actuator axis with a fitting screw(2).
Use a 1.5mm Allen key for this.
Fit the sealing element (1) onto the fitting screw
hole (2).
Fasten the pickup window (see 6.5.2 "Fitting the
pickup window" [}38]).