6 Repairs to SmartFeeder 4 mm X / Xi 6.17 Foil container Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 89 ► Fasten the right side cover with the marked screws (see also th…

6 Repairs to SmartFeeder 4 mm X / Xi
6.17 Foil container
88 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
6.17.2 Foil box
Spare part required
Fig.27: Foil box
Feeder module Item no. Designation
SmartFeeder 4mmX
SmartFeeder 4mmXi
03125663-xx Foil box X4Smart V2
Tools required
●
Phillips screwdriver 0.9Nm
●
TORX screwdriver 0.6Nm, size T8
●
Flat-bladed screwdriver size 1
●
Tweezers
6.17.2.1 Removing the foil box
► Carefully place the feeder module with the left side down on a stable, level and clean surface.
► Remove the right side cover (see 6.3.3 "Removing the Right Side Cover" [}31]).
► Remove the 4 TORX screws marked in the dia-
gram. (1)
Use a T8 TORX screwdriver for this.
► Remove the Phillips screw marked in the dia-
gram. (2)
► Remove the cover flap with the shaft.(3)
► Carefully remove the insertion foil container.

6 Repairs to SmartFeeder 4 mm X / Xi
6.17 Foil container
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 89
► Fasten the right side cover with the marked
screws (see also the notes at 6.3.4
"Fitting the
Right Side Cover" [}32]).
► Carefully place the feeder module with the right
side down on a stable, level and clean surface.
► Remove the spring behind the rocker.
► Remove the left side cover assembly (see 6.3.1
"Removing the Left Side Cover" [}30]).
► Remove the rear sliding guide (see 8.2.1 "Re-
moving the Rear Sliding Guide" [}173]).
► Loosen the screw marked B with a Phillips
screwdriver.
► Loosen the 3 screws marked A with a TORX
screwdriver.
ð The lower stiffener (1) also loosened will be
pulled off the foil box at a later time.
► Remove the TORX screw fastening the filler
piece for the splice sensor.

6 Repairs to SmartFeeder 4 mm X / Xi
6.17 Foil container
90 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
► Remove the two TORX screws fastening the foil
box to the empty tape duct.
► Remove the two TORX screw fastening the foil
box (1)
to the foil stripping unit (2).
► Open the connection X202 on the control board.
► Remove the flat ribbon cable leading to the con-
trol panel.
► Reach between the foil box and the righthand
side cover with the finger of your right hand.(1)
► Use your left hand to carefully lift the top stiffener
together with the foil stripping unit.(2a)
► At the same time, press the foil box down with
the thumb of your right hand.(2b)
The connection between the foil stripping unit and the
foil box should now open.(3)
If the connection does not open:
► Move the rocker, to separate the tamp wheels of
the foil rocker from the rocker.