6 Repairs to SmartFeeder 4 mm X / Xi
6.6 Splice sensor
44 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
6.6.2 Performing a function test
Prerequisite: to test the splice sensor, you need a test tape i.e. a piece of tape with a splice rivet
pressed onto it.
Fig.8: Control panel
1. LED 8 – 8mm pitch 6. FORWARDS button
2. LED 4 – 4mm pitch 7. BACKWARDS button
3. LED 2 – 2mm pitch 8. FOIL button
4. LED 1 – 1mm pitch 9. SET button
5. LED M – menu
Shines when an operator menu is active
Place the feeder module on a single slot EDIF or on a changeover table for X feeders which is
connected to a placement machine.
Press and hold the gray SET button on the control panel(9) until the function test is enabled.
Press the yellow FOIL button four times briefly(8).
After the first press of the FOIL button, the LEDM will switch on.
After the second press, LED1 will also be switched on.
After the third press, LED2 will also be switched on.
After the fourth press, LED 4 will also be switched on.
The menu for the splice sensor function test has now been selected.
Release the gray SET button, the function test has now been enabled.
Move the test tape with the splice rivet pressed onto it up to the sensor.
If the splice sensor recognizes the splice rivet, LED 8 will shine.
If LED 8 stays off, this means that the splice rivet was not recognized. Check whether the splice
sensor was fitted properly.
If the sensor is then not recognized, check whether the flat ribbon cable for the splice sensor has
been correctly fastened (see section 6.16.2
"Fitting the control board" [}83]).
If the sensor is still not recognized, this indicates that it is probably defective and needs replacing.
To end the test mode, press any button on the control panel. The test mode will also be ended
automatically after 1 minute.
After ending the test mode, the control panel will show the pitch currently set.
6 Repairs to SmartFeeder 4 mm X / Xi
6.7 Drives
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 45
6.7 Drives
6.7.1 Foil motor
Required spare part
Fig.9: Motor coupling/foil disposal X8Smart
NOTICE
Observe the function status of the feeder module
The SmartFeeder 4mmX motors have been converted from the 8 bit encoder to the 12 bit
encoder.
The feeder module firmware is able to supply the 8 bit and the 12 bit encoder. However, the
SmartFeeder 4 mm X can only operate either the 8 bit or the 12 bit motors.
For this reason, when replacing the motor of the foil disposal unit, pay attention to the func-
tion state (FS) of the feeder module and select the spare part which corresponds with it.
Feeder module Position Item no. Designation
SmartFeeder 4 mm X
00141368-xx (up to FS 03
)
1 03119123Sxx Motor assembly for foil disposal X8Smart
(8 bit)
SmartFeeder 4 mm X
00141368-xx (> FS 03
)
SmartFeeder 4 mm Xi
1 03170813-xx Motor for foil drive with 12 bit encoder
SmartFeeder 4mm X
SmartFeeder 4 mm Xi
2
3
4
03028610-xx
03012488-xx
03042536-01
Bearing block, ceramic
SN 213307-H-M2 x 2.5-A2
(for fitting the bearing block)
ISO 4762 - M 2.5 x 12-A2-70
(for fitting the motor)
Tools required
Phillips screwdriver 0.9Nm
Flat-bladed screwdriver size 3
TORX screwdriver 0.6Nm, size T8
Angled Allen key, size 2
Allen key 0.9 Nm, size 4
Tweezers
Required consumables
Grease Klübersynth GE 14-151
6 Repairs to SmartFeeder 4 mm X / Xi
6.7 Drives
46 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
6.7.1.1 Removing the Foil Disposal Motor
Carefully place the feeder module with the right
side down on a stable, level and clean surface.
Remove the left side cover (see 6.3.1 "Removing
the Left Side Cover" [}30]).
Remove the 3 Phillips screws(1) marked in the
diagram from the bearing cap for the foil gear.
Lift the bearing cap(2) up with a pair of tweezers
or a small screwdriver(3)
and remove it.
Loosen the spiral gear(4) on the foil disposal
with a size 4 Allen key(5)
.