Service Manual SIPLACE SmartFeeder.pdf - 第234页
8 Repairs to SmartFeeder 2x8 mm X / Xi 8.16 Handle with control panel 234 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 8.16 Handle with control panel Spare part required …

8 Repairs to SmartFeeder 2x8 mm X / Xi
8.15 Leaf spring
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 233
8.15 Leaf spring
Spare part required
Fig.76: Leaf spring tape infeed
Feeder module Item no. Designation
SmartFeeder 2x8mmX
SmartFeeder 2x8mmXi
03071618-xx Leaf spring tape infeed /X2x8 PT V1
Tools required
●
Phillips screwdriver
●
TORX screwdriver size T8
8.15.1 Removing the Leaf Spring Infeed
► Place the feeder on a stable, level and clean sur-
face.
► Depending on which leaf spring is damaged,
remove either the left or right side cover (see
8.3.1
"Removing the Left Side Cover" [}174],
8.3.3
"Removing the Right Side Cover" [}175]).
► Lift the leaf spring straight up and out of the hold-
ing device.
8.15.2 Fitting the Leaf Spring Infeed
► Insert the leaf spring vertically (from above) into
the holding device.
► Ensure the leaf spring is sitting correctly.
► Fasten the left or right side cover (see 8.3.2 "Fit-
ting the Left Side Cover" [}175], 8.3.4 "Fitting the
Right Side Cover" [}176]).

8 Repairs to SmartFeeder 2x8 mm X / Xi
8.16 Handle with control panel
234 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
8.16 Handle with control panel
Spare part required
NOTICE
New spare part
Spare part "Handle X2x8" [03072432Sxx] is no longer available.
This item can only be replaced as a complete unit.
The new "Handle X2x8 assy. [03170776-xx] is available as a compatible replacement.
It is now possible to replace individual parts of this handle.
Fig.77: Handle X2x8 assy.
Feeder module Item no. Designation
SmartFeeder 2x8mmX 03170776-xx Handle X2x8 assy. (prefitted with flat ribbon cable)
SmartFeeder 2x8 mm Xi 03172629-xx Handle X2x8i assy. (prefitted with flat ribbon cable)
Tools required
●
Phillips screwdriver 0.6Nm
●
TORX screwdriver size T8, 0.6Nm
●
Tweezers

8 Repairs to SmartFeeder 2x8 mm X / Xi
8.16 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 235
8.16.1 Removing the handle assembly
► Remove the left and right side cover (see 8.3.1
"Removing the Left Side Cover" [}174] and 8.3.3
"Removing the Right Side Cover" [}175]).
► Remove the cover on the foil container.
Carefully place the feeder module on its right side.
► Remove the two pressure springs from the rock-
ers.
► Open the bar on the flat ribbon connection on the
control board.(1)
► Unplug the flat ribbon cable form the connection.
► Carefully pull the flat ribbon cable completely out
through the feedthrough on the tape duct.(2)
► Carefully pull the flat ribbon cable off the adhes-
ive points.
► Remove the two screws marked in the diagram,
which are fastening the handle.
► Stand the feeder module up.
► Open the foil disposal flap.
► Push the handle up to the right-hand side and out
of the feeder module base.
► Close the foil container flap.