4 X Feeder Verification System Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 21 4 X Feeder Verification System Fig.1: SIPLACE X Feeder Verification System The SIPLACE X…

3 X-Feeder Test Station
3.2 Rare Errors
20 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
3.2 Rare Errors
Some of the feeder modules show the following error images in rare cases. These errors can have
highly complex causes:
●
Communication problems at the machine
●
Problems at the pickup position
Communication problems at the machine
Symptom:
The test with the X-Feeder Test Station
was completed without errors but the feeder module exper-
ienced a communication problem at the machine.
Example:
The feeder module does not log onto the machine.
Procedure for fixing the fault:
► Clean the EDIF on the feeder module and on the machine.
Try again to log the feeder module onto the machine.
► Set the feeder module up at another machine.
Diagnosis:
If the error disappears after cleaning or after you have set the feeder module up at a different
machine, this indicates a machine error.
If the communication problem to the feeder module remains, this indicates that the feeder module
is defective and needs to be sent to the manufacturer for repairs.
Problems at the pickup position
if the feeder module has continued pickup problems and if you can rule out configuration errors,
this indicates that the feeder module is defect and needs to be sent to the manufacturer for repairs.

4 X Feeder Verification System
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 21
4 X Feeder Verification System
Fig.1: SIPLACE X Feeder Verification System
The SIPLACE X Feeder Verification System (FVS) [03126186-xx] allows you to use various test
sequences to check all feeder module components and to optically test the repeat accuracy of the
X feeder pickup position. The detailed test reports can be saved and printed as PDF or CSV files.
The X Feeder Verification System can be used to test the following feeder modules:
●
X Feeder 4-88mm
●
SmartFeeder 2x8 mm X
●
SmartFeeder 4 - 88 mm X
With the help of the X Feeder Verification System you can check:
●
The functionality of the drives
●
The functionality of the control panels and buttons
●
The functionality of the splice sensors
●
The functionality of the rocker
●
The repeat accuracy of the pickup position
For a detailed description of the SIPLACE X Feeder Verification System refer to the user guide for
the product, item no. 00198272-xx.

4 X Feeder Verification System
22 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020