YSM40R_Mainte_E.pdf - 第129页
3-59 3 Periodic maintenance items 5 Remo ve the belt from the pulley . Check that the removed belt is not cracked, worn and frayed. If the belt is cracked or worn, replace it referring to "2.1 Replacing the conveyor…

3-58
3
Periodic maintenance items
5.3 Conveyor
5.3.1 Inspecting conveyor belt and cleaning guide and pulley
1
Prepare for work.
e
1. Remove all items sensitive to magnetic
fields such as wristwatches and magnetic
ID cards.
2. Press the emergency stop button to put
the machine in emergency stop.
3. Use the CLAMP ON/OFF switch to lower
the feeder exchange carriage and
detach it.
4. Remove the tape cutter duct.
5. Place a square cloth on the push-up
plate.
2
Detach the board clamp assembly.
Use a hex wrench (2.5) to remove the bolts (4
places shown in the figure at right) that
mount the board clamp assembly.
53371-N9-00
c
CAUTION
Do not remove any bolts other than the 4 bolts shown in
the figure at right.
3
Put a mark at the pulley position.
Using an oil-based pen, put a mark to
indicate the position of the bolt that mounts
the tensioner pulley.
53372-N9-00
4
Loosen the belt.
1. Use 2 hex wrenches to loosen the belt
tensioner pulley and move it to the end
of the tension adjusting slot (in the
loosening direction).
Hex wrench on pulley side : 5 mm
Hex wrench on bolt side : 4 mm
2. Use a flat-head screwdriver to remove
the end pulley shaft next to the tensioner
pulley loosened, and then remove the
end pulley.
53373-N9-00
c
CAUTION
Use care to avoid losing the washers.
Step 2
Board clamp assembly
Board clamp assembly mounting bolts
Removing the board clamp assembly
Marking the pulley position
Step3
Use an oil-based pen to mark the pulley position.
Loosening the belt
Step 4
Loosen this pulley.
Remove this pulley.
Hexagon wrench (5)
Hexagon wrench (4)
WasherPulley shaft

3-59
3
Periodic maintenance items
5
Remove the belt from the pulley.
Check that the removed belt is not cracked,
worn and frayed.
If the belt is cracked or worn, replace it
referring to "2.1 Replacing the conveyor
belt" in Chapter 6.
6
Clean the guides and pulleys.
1. Use a vacuum assembly (option) to
suction the belt wear debris on the belt
guides and sensors, etc.
2. Use a plastic spatula or similar tool to
remove the belt wear debris adhering to
the outer peripheral surface of the
pulleys.
3. Use a brush or similar tool to remove the
belt wear debris caught in the belt
guides.
53394-N9-00
c
CAUTION
Use a plastic spatula and brush to avoid scratching the
pulleys and guides.
c
CAUTION
Do not use a solvent (IPA, etc.) unless the guides and
pulleys are excessively dirty. If using a solvent, be
careful not to spill the solvent on the bearing in the
pulleys during cleaning.
7
Reattach the belt.
1. Temporarily place the belt on the belt
tensioner pulley.
2. Place the belt on the end pulley
removed in Step 4 and mount it with the
pulley shaft together with the washer.
3. Move the belt tensioner pulley to the
position marked in Step 4 and tighten the
bolt while applying tension.
4. If there is a slack in the belt, adjust the
position of the belt tensioner pulley to
apply proper tension.
53374-N9-00
n
NOTE
The specified conveyor belt tension for this machine is as follows. Use a tension gauge to adjust the belt tension as
needed. Stage 1 : 260 to 320Hz / Stage 2 : 180 to 220Hz
c
CAUTION
The tightening torque for the belt tensioner pulley is 5.5 N·m. Be careful not to overtighten.
8
Attach board clamp assembly.
1. Attach board clamp assembly to the original position. Mount it by tightening 4 bolts with hex wrench
(2.5).
2. Remove square cloth.
9
Return the tape cutter duct to the original position.
Tension measurement point
Step 7
Tension measurement point
(outer side of each lane)
Step 6
Spatula
(made of plastic)
Brush
Belt guides
Outer peripheral surface of pulley
Outer peripheral surface of pulley
Belt wear debris
sticking to pulley
Cleaning the guide and pulley

3-60
3
Periodic maintenance items
5.3.2 Cleaning and greasing the hexagon spline
The cleaning and lubrication procedures for the conveyor's IN and OUT port hexagon splines are given below.
See "Chapter 5 Lubricating points" for lubricating points and lubricating type.
1
Set the conveyor width to the
maximum.
Manually set the conveyor width to the
maximum.
2
Prepare for work.
e
1. Remove all items sensitive to magnetic
fields such as wristwatches and magnetic
ID cards.
2. Press the emergency stop button to put
the machine in emergency stop.
3. Use the CLAMP ON/OFF switch to lower
the feeder exchange carriage and
detach it.
3
Clean the hexagon spline.
Wipe away old grease and dirt from the
entire hexagon spline with a lint-free cloth
(for clean room).
53376-N9-00
n
NOTE
If it is difficult to clean the hexagon spline due to the
tape cutter duct, then remove the tape cutter duct.
Note, however, that emergency stop cannot be
canceled when the tape cutter duct is removed. So
you will have to reattach it to cancel emergency stop.
4
Wipe the rest of the hexagon spline.
e
1. Set the feeder exchange carriage and
cancel emergency stop.
2. Narrow the conveyor width manually,
press the emergency stop button again,
and detach the feeder exchange
carriage.
3. Wipe the rest of the hexagon spline that
could not be wiped.
5
Apply grease.
Apply a uniform coat of the specified grease
(NSL) by hand over the surface of the
hexagon spline. As with Steps 3 to 4, adjust
the conveyor width to apply grease over the
entire hexagon spline.
53377-N9-00
Cleaning the hexagon spline
Step3
Cleaning cloth
Hexagon spline
Applying grease
Step 5
Apply a thin coat of
grease in a uniform
manner.
Grease