4 Working with Smart Pin Support at the Station 4.1 Smart Pin Support Setup View 96 User Manual / Bedienungsanleitung SIPLACE X-Series S, SX1/SX2 V2 Smart Pin Support Operation and Configura- tion 05/2019 Fig.38: Suppor…

100%1 / 114
4 Working with Smart Pin Support at the Station
4.1 Smart Pin Support Setup View
User Manual / Bedienungsanleitung SIPLACE X-Series S, SX1/SX2 V2 Smart Pin Support Operation and Configura-
tion 05/2019
95
4 Working with Smart Pin Support at the Station
The Smart Pin Support function is supported by the station software as of the 706.0 version.
Prerequisites
The steps and prerequisites described in the preceding chapters have been performed and/or
are complied with.
The station is ready for operation.
A job with a setup containing a board with defined support pin positions has been defined in
SIPLACE Pro and downloaded to the station.
It is assumed that the support pins were automatically detected in the Autoconfiguration and
that the operator does not have to initiate special actions for the support pin positioning.
4.1 Smart Pin Support Setup View
Switch to the Feeders, components and nozzles view.
Switch to the Setup - Locations view.
The following dialog box will open.
Fig.37: Setup – Locations (sample X4 S)
In the center, the Smart Pin Support Setup (1) will be displayed either below and/or above the
conveyor button (2).
Click on the Smart Pin Support Setup button (1).
The following dialog box will open.
4 Working with Smart Pin Support at the Station
4.1 Smart Pin Support Setup View
96 User Manual / Bedienungsanleitung SIPLACE X-Series S, SX1/SX2 V2 Smart Pin Support Operation and Configura-
tion 05/2019
Fig.38: Support pins in processing area 1 (sample X4 S)
This view will be displayed per placement area. The yellow area (1) will display the area on the lift-
ing table on which support pins may be placed. On the lifting table the set support pin positions (2)
will be displayed with the existing support pins.
The support pin positions will be marked with crosshairs in different colors (see section 4.4 "Testing
Placement Head with Pin Picker Manually" [}100], figure Support pin functions tab (sample SX2)):
Green: a support pin is present at the support pin position
Red: no support pin at the support pin position
Gray: the support pin position is notmandatory (optional)
The garages (3) and the available support pins (4) will be displayed for the pin magazines.
The Smart Pin Support Setup view is updated dynamically. This means, whenever an action was per-
formed in the view or a change was registered by the monitoring software, an updated view will appear.
The following functions are provided in this view:
Scan support pins
The support pins on the lifting table and in the pin magazine will be scanned with the PCB camera.
Scan pin magazines
The garages will be scanned with the PCB camera.
Return to magazines
All support pins will be removed from the lifting table and placed back into the pin magazines.
Place on lifting tables
Support pins will be placed on the lifting tables.
Detailed information about the functions can be found in the Online Help for the station software.
Normally, no further actions are required by the operator. The Smart Pin Support job will be per-
formed automatically.
NOTICE
New behavior as of station software V707.0 and SIPLACE Pro V11.1
If an existing pin configuration on the lifting table is to be replaced by a new pin configura-
tion, the pins will not be put back into the pin magazine. Instead, the existing pins will be
moved on the lifting table. This shortens the time for the configuration change.
4 Working with Smart Pin Support at the Station
4.2 Checking the Support Pin Positions – Setting Time Interval
User Manual / Bedienungsanleitung SIPLACE X-Series S, SX1/SX2 V2 Smart Pin Support Operation and Configura-
tion 05/2019
97
4.2 Checking the Support Pin Positions – Setting Time
Interval
Navigate to the SettingsMachine options dialog box.
Select the Fault detection tab.
The following dialog box is opened.
Fig.39: Checking positions of support pins periodically
Activate the Check positions of support pins periodically option to use the function.
Set the lapse of time in minutes after which the support pin positions have to be checked
under Time interval [min].
After the set time interval has elapsed, the conveyor interface will be locked. All boards in the
machine will be completed and moved out of the machine. As soon as the machine is empty, the
support pin positions will be checked and corrected, if necessary.
If an existing support pin was not found, a corresponding error message is displayed.
Remove this support pin manually and confirm the error message.
The support pin will then be automatically reset.
The check will be performed before the set time interval has elapsed if the station is empty.