00191369-01.pdf - 第120页

3 Introduction and Basic Concepts User’ s M anual SIPLACE HS -50 3.3 User Interface - Views and Menus Software Version SR.501.xx Edition 01/99 118 1HZ FOXVWHU   In the "S tand alon e" control mode, you can…

100%1 / 442
User’s Manual SIPLACE HS-50 3 Introduction and Basic Concepts
Software Version SR.501.xx Edition 01/99 3.3 User Interface - Views and Menus
117
&RQWURO 0R GHV
6WDQGDORQH(for test purposes only)
This control mode allows you to load a cluster (placement program) for test and service
purposes from the station computer using the menu item "New cluster..." .
The necessary data must be located on the station computer’s hard disk.
*(0+RVW
In this control mode, clusters can only be specified by the host computer.
The necessary data must be located on the host computer’s hard disk.
NOTE
This setting must be activated if you want to download cluster data from the host computer to
the station computer via the GEM interface. The procedure for doing this is described in
Chapter. 13.
This control mode cannot be set in the current software version since the "GEM Interface"
option has not yet been implemented.
/LQH&RPSXWHU
If a cluster has been prespecified at the station, all the necessary associated data is loaded
from the line computer. The data must be located on the line computers hard disk.
NOTE
By default, clusters and set-ups should be prespecified by the line computer.
If the line computer is powered down via "Shut down" and then rebooted, all the connected
stations must also be rebooted.
6,3/$&(3UR
This control mode cannot be set in the current software version.
Å Activate the radio button for the required control mode.
Å Click 2. to make your settings active.
3 Introduction and Basic Concepts User’s Manual SIPLACE HS-50
3.3 User Interface - Views and Menus Software Version SR.501.xx Edition 01/99
118
1HZFOXVWHU
In the "Stand alone" control mode, you can load the data for a selected cluster from the
station computer’s hard disk.
Å Click the menu item 1HZFOXVWHU
Å Now enter the name of the required cluster in the displayed text box and click 2. to
confirm. The cluster data is now loaded.
NOTE
The data, including the fiducial and package form data, of the last cluster successfully
prespecified by the line computer, is now saved on the station computer’s hard disk under the
cluster name "AKTUELL" and can be loaded by entering this name.
6RIWZDUH
This menu item is used to activate the test commands (test functions) for checking a variety
of machine components.
NOTE
This menu item can only be called from the "Service" access level.
DANGER
Settings for test commands and test command execution should be performed by service
engineers only.
Å Click the menu item 6RIWZDUH
The following window is opened.
User’s Manual SIPLACE HS-50 3 Introduction and Basic Concepts
Software Version SR.501.xx Edition 01/99 3.3 User Interface - Views and Menus
119
Å Select the tab corresponding to the required machine component and activate/deactivate
the test commands by clicking the corresponding checkboxes.
Å Click $FFHSW to set the software options.
NOTE
When the station is rebooted, the software options are reset to their original settings.
&\FOHPRGH$ OWW
You use this menu item to switch the station to cycle mode (e.g. to localize errors).
Å Click the menu item &\FOHPRGHor press the key combination$/7+W. The "Cycle mode"
settings box is opened.
Å Click the 2Qradio button to activate cycle mode or the 2II radio button to deactivate it.
Å Click the 2. button. Cycle mode is now either activated or deactivated.
NOTE
In cycle mode, you must press the Start button on the machine for every operating step.
/RDGWDEOHSURJUDP
This menu item allows you to reload the table program into the memory of the table program
controller. You may need to do this, for example, if a machine error has resulted in the loss of
the table program.