00191369-01.pdf - 第142页
4 Placement Functions User’s Manual SIPLACE HS -50 4.3 Feeders Software Version SR.501.xx E dition 01/99 140 )HHGH UV Å Click on the icon in t he tool bar in th e Main view . The user inte rface s witches to one o …

User’s Manual SIPLACE HS-50 4 Placement Functions
Software Version SR.501.xx Edition 01/99 4.2 Error Display
139
*HQH UDO(UURUV9LH Z
0HDQLQJRIWKH(QWULHVLQWKH7DEOHIRU*HQHUDO(UURUV
– 1R
Error number of the corresponding error.
– ,QIR,QIR
These are only intended for internal use by Siemens.
– '(9
Short description of the sender of the error
– (
Error counter (see also Section 4.2.2.1
.
±7H[W
Description of the corresponding error.

4 Placement Functions User’s Manual SIPLACE HS-50
4.3 Feeders Software Version SR.501.xx Edition 01/99
140
)HHGHUV
Å Click on the icon in the toolbar in the Main view.
The user interface switches to one of the views described in the following sections.
NOTE
When the "Feeders" menu function is called for the first time after starting the SC software,
then the "Empty tracks" view is displayed first (see Fig. 4.3 - 1).
(PSW\7UDFNV9LHZ
If the placement head cannot pick a component from a track after 3 attempts, then it will not
use this track again. This track is added to the "Empty tracks" list.
As soon as the feeders in the empty tracks are filled with components, this fact must be con-
firmed so that the placement head can access these tracks again. This is done by refilling the
empty tracks using the "Refill track" function. You can refill individual tracks or all tracks of a
location at the same time when refilling empty tracks with "Refill track".
NOTE
The manual refilling of tracks that contain components with specified component barcodes is
only possible using "Refill track" when the "Component verification with barcode" option in the
machine options is not
active.
If the "Component verification with barcode" option is active, then a corresponding note is dis-
played instead of the buttons for locations 1 through 4 (see Fig. 4.3 - 2).
Å Click on the icon, if necessary.
The "Empty tracks" view is displayed (see Fig. 4.3 - 1
).

User’s Manual SIPLACE HS-50 4 Placement Functions
Software Version SR.501.xx Edition 01/99 4.3 Feeders
141
.H\WR)LJ
(1) "Empty tracks" view
(2) "Omit components" view
(3) "Trays" view
(4) "Linear feeder" view
NOTE
The "Trays" view with the functions to display and change the inventory levels of
flatpack trays is currently irrelevant for model SIPLACE HS-50 machines and is therefore not
described in this operating manual.
1234