00191369-01.pdf - 第32页

1 Introduction User Manual HS-50 1.10 Setting up t he placement system Software Version 5.01 01/99 Issue 30  7 UDQVSRUWFRQILJXUDWLRQDQGWUD QV SRUW DWLRQ The foll owing com ponents are not installe d when the pl …

100%1 / 442
User Manual HS-50 1 Introduction
Software Version 5.01 01/99 Issue 1.10 Setting up the placement system
29
 6HWWLQJXSWKHSODFHPHQWV\VWH P
 7UD QVSRUWGLPHQVLRQV
The placement system mounting kit (A) on the input side can be dismantled for transportation
purposes, which will reduce the width of the machine from 2380 mm to 1960 mm.
A Mounting kit which can be dismantled for transportation purposes.
B Points for attaching the fork-lift truck (fork length 2500 mm)
The PCB conveyor height is 830 mm ± 15 mm (or 952.5 mm ± 15 mm in accordance with the
SMEMA standard). The height specifications for the machine will change accordingly.
420
1790 (1912,5 SMEMA)
1592
(1714,5 SMEMA)
1960
2380
800
A
B
B
830±15
(952,5 ± 15 SMEMA)
1 Introduction User Manual HS-50
1.10 Setting up the placement system Software Version 5.01 01/99 Issue
30
 7UDQVSRUWFRQILJXUDWLRQDQGWUD QV SRUWDWLRQ
The following components are not installed when the placement system is delivered from the
factory:
keyboards
monitors
fault indicator lamps and
component tables
Å Install the dismantled components for commissioning.
Å Use a fork-lift truck to transport the placement system:
minimum fork length 2000 mm if the mounting kit is dismantled.
minimum fork length 2500 mm if the mounting kit is still fitted.
Å Attach the fork-lift truck only at the indicated points.
 4XDOLW\RIWKHIRXQGDWLRQ
Å Ensure that
you set up the placement system on a firm and non-vibrating foundation.
the load bearing capacity per unit area of the foundation is greater than 1000 kg/m².
 &RPSUHVVHGDLUVXSSO\
The pressure of the compressed air supply must be 5.5 bar ± 0.5 bar.
The compressed air must conform to the above specification.
This can be achieved with
oil-free compressors, e.g. Atlas, Copco type ZR4
compressed air washer/driers
micro-filters, series X, e.g. from Zander
 3RZHUVXSSO\
The power socket must be fused with the following fuse ratings:
3 x 16 A for 3 x 400 VAC
3x32A for 3x204VAC
3x16A for 3x460VAC
User Manual HS-50 1 Introduction
Software Version 5.01 01/99 Issue 1.10 Setting up the placement system
31
 6HWWLQJXSWKHSODFHPHQWV\VWHP
Å Raise the placement system using the fork-lift truck and adjust the feet until there is a gap
of 830 mm (952.5 mm SMEMA height) between the top edge of the PCB conveyors and
the bottom edge of the feet.
Å Leave a gap of 1 to 3 mm between the PCB conveyors of the placement system.
Å Use a cord pulled tight to ensure that all the placement systems are exactly in line with one
another.
Å Adjust each placement system using a spirit level with an accuracy of 0.02 mm/m.
Å Lock the feet in position.
Å Check the placement system again using the spirit level and correct the settings, if neces-
sary.
CAUTION
Make sure that you remove all the shipping braces from the placement system.
Å Fit any components that were dismantled for dispatch.
Å Connect all the electrical and pneumatic lines.
RISK OF DEATH
The electrical connection work MUST be carried out only by appropriately trained and
certified personnel.