User Manual HS-50 6 Vision functions Software-Version 5.01Edition 01/99 6.4 Access to the ’Teach Fiducial’ and ’Test Component’ Options 199 /LPLWYDOXHVI RUTXDOLW\P HDVXUHPHQW   Components ex ceeding the limi t valu…

100%1 / 442
6 Vision functions User Manual HS-50
6.3 Component Vision System Software-Version 5.01 Edition 01/99
198
.H\WR)LJ
(1) Axis of symmetry
&ULWHULDIRULUUHJXODUFRPSRQHQWV
Definition:
A component is deemed to be irregular when it does not satisfy the conditions for regular compo-
nents.
Additional conditions for centering with the component vision system:
In any one row up to 3 different lead types are permitted.
In any one row up to 15 groups are permitted.
3LWFKGHYLDWLRQ
The pitch deviation (which is the distance from the center of one lead to the center of the next) can
be edited separately for each component in the GF editor. If this value is exceeded during the vi-
sion inspection, the component will not be centered and therefore not placed.
X
Pin 1
Y
X
Pin 1
Type 1
Group 1
Type 2
Group 1
Type 1
Group 2
Type 3
Group 1
Type 2
Group 2
User Manual HS-50 6 Vision functions
Software-Version 5.01Edition 01/99 6.4 Access to the ’Teach Fiducial’ and ’Test Component’ Options
199
/LPLWYDOXHVIRUTXDOLW\P HDVXUHPHQW
Components exceeding the limit values for quality measurement will be rejected and, therefore,
not placed:
Difference in the number of leads between the original and the model.
Pitch deviation larger than the value in the GF file.
Larger orthogonality error than specified in the GF file.
Larger deviations of the external dimensions.
Deviation of the central point greater than the permitted positional tolerance for pick-up.
 $FFHVVWRWKH¶7HDFK)LGXFLDO¶DQG¶7HVW&RPSR
QHQW¶2SWLRQV
Access to the ’Teach fiducial’ and ’Test component’ options is only available to user class Line en-
gineer and higher. The ’Teach fiducial’ and ’Test component’ icons will remain grayed out until user
classes ’Line engineer or ’Service engineer’ have been selected. The grayed-out icons will be ac-
tivated and appear black, indicating that the options are available.
6HOHFWLRQRIXVHUFODVVHV
Å In the menu bar of the 0DLQYLHZmenu click on the 2SWLRQVpull-down menu.
Å Click on the $FFHVVOHYHOoption. The user class option box will drop down.
Å Select the appropriate user class.
6 Vision functions User Manual HS-50
6.4 Access to the ’Teach Fiducial’ and ’Test Component’ Options Software-Version 5.01 Edition 01/99
200
You can also protect the user classes /LQHHQJLQHHUand 6HUYLFHHQJLQHHU by entering a pass-
word at the station computer which will then be used to control access.
Å In the menu bar of the 0DLQYLHZmenu click on the 2SWLRQVpull-down menu.
Å Click on the $FFHVVOHYHOoption. The user class option box will drop down.
Å Click on the &KDQJHSDVVZRUG. The input box for the password will drop down.
Å Type in the password and then confirm.
Å Click on 2.to accept the password or &DQFHOto reject it.
Å Move the mouse pointer over the 7HDFKILGXFLDOor 7HVWFRPSRQHQWoption. The status line
will display a brief explanatory text for the option in question. You can also use the F8 or F9
function keys to access the options. The 9LHZdrop-down menu will list the allocations of the
function keys and the individual options.
Å Click on either of the two icons (buttons). The screen will then display either the 6HOHFWILGXFLDO
menu or the6HOHFWSDFNDJH IRUP menu depending on whether you have selected the 7HDFK
ILGXFLDOoption or the 7HVWFRPSRQHQWoption (see Figs. 6.4 - 2 and 6.4 - 3).
’Test component’ icon’Teach fiducial’ icon