2 Operational Safety User Manual HS-50
2.3 Residual voltages in the servo unit and discharge times when the placement system is switched offSoftware-Version 5.01 Edition 01/
99
72
1. Position of the servo units
2. Voltage measuring unit on the servo unit
 2SHUDWLQJYROWDJHVUHVLGXDOYROWDJHVDQGGLVFKDUJHWLPHVDIWHUSUHVVLQJWKH
HPHUJHQF\VWRSPXVKURRPKHDGSXVKEXWWRQ
7HVWVRFNHWV;;
;PHDVXUHGWR;
*1'
9ROWDJHLQQRUPDO
PRGH
5HVLGXDOYROWDJH
GXULQJHPHUJHQF\
VWRS 'LVFKDUJHWLPHV
X2 + 30 VDC + 30 VDC -
X3 + 100 VDC < 10 VDC 50 sec
X4 + 200 VDC < 10 VDC 7 sec
User Manual HS-50 2 Operational Safety
Software-Version 5.01Edition 01/99 2.4 Disabling the compressed air supply and releasing the pressure
73
 5HVLGXDOYROWDJHVDQGGLVFKDUJHWLPHVDIWHUVZLWFKLQJRIIDWWKHPDLQVZLWFK
CAUTION The following conditions must be fulfilled before switching off the placement
system (apart from in emergencies) in order to avoid the loss of data:
the placement system must have stopped transmitting machine, set-up and cluster data.
the placement system must have stopped processing the PCBs.
the placement system must have completed the start-up phase.
the Windows NT operating system must have been shut down correctly.
 'LVDEOLQJWKHFRPSUHVVHGDLUVXSSO\DQGUHOHDVLQJ
WKHSUHVVXUH
The compressed air operating pressure is permanently set to 5.3 bar. The position of the com-
pressed air unit is indicated by item 4 in the diagram. The compressed air supply to the placement
system may be interrupted using the shut-off valve (item 1 in the diagram).
Å Open the safety doors.
Å Turn the lever of the shut-off valve (item 1 in the diagram) from the vertical to the horizontal
position.
Å Check the operating pressure gauge and the pressure gauge for the compressed air supply to
the stopper (items 2 and 3 the diagram). When the placement system is switched on, the pres-
sure drops to 0 bar within 1 minute.
CAUTION When the machine is switched on, do not use the stop valve to interrupt the
compressed air supply for more than 30 minutes. If you need to shut off the pneumatic system for
longer in order to carry out maintenance or servicing work, you must switch the placement system
off at the main switch and disconnect it from the power supply.
7HVWVRFNHWV;;;
PHDVXUHGWR;*1'
5HVLGXDOYROWDJHZKHQPDLQ
VZLWFKLVVZLWFKHGRII 'LVFKDUJHWLPHV
X2 < 10 VDC < 2 sec
X3 < 10 VDC < 50 sec
X4 < 10 VDC < 7 sec
2 Operational Safety User Manual HS-50
2.4 Disabling the compressed air supply and releasing the pressure Software-Version 5.01 Edition 01/99
74
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury.
1. Shut-off valve lever in the CLOSED position
2. Operating pressure gauge
3. Pressure gauge for the component table operating pressure
4. Position of the compressed air unit on the placement system