2.2 Safety equipment Software-Version 5.01 Edition 01/99
66
3URWHFWLYHFRYHUVZLWFKHV,WHPLQ)LJDQGRWKHUFRYHUVZLWF KHV,WHP LQ)LJ
These switches check whether the protective and other covers are closed. When the covers are
closed, the safety contact is closed and the signalling contact is open. If one of the covers is ope-
ned, the safety circuit opens and the signalling circuit closes. The individual components will either
be activated or deactivated, depending on the position of the key switch (Item 5).
3URWHFWLYHFRQWDFWRUFRPELQDWLRQ7.,WHPLQ)LJ
The protective contactor combination is contained in the power supply unit. It is not activated or
deactivated if safety-related functions fail.
.H\VZLWFKLQSRVLWLRQ,WHPLQ)LJ
PLEASE NOTE The key switch remains open, i.e. in position "0" for normal mode.
The protective contactor combination (PCC) trips when one of the protective or other covers is
opened. The link voltage (200 V) to the gantry axes is switched off and the link voltage for the star
axes (100 V) is reduced to 6 VDC. All modules are deactivated.
.H\VZLWFKLQSRVLWLRQ,
WARNING
The protective covers must only be opened by appropriately qualified and trained personnel
when the key switch is closed (position "I").
The protective contactor combination (PCC) trips when one of the protective or other covers is
opened. The link voltage to the gantries is switched off and the link voltage for the star axes is
reduced to 6 VDC. The star of the placement head can be paced at a lower speed when the cover
is open. The following modules:
– PCB stopper
– lifting table motors and PCB clamping
– used tape cutters
are deactivated.
6RFNHWVIRUWKHFRPSRQHQWFKDQJHRYHUWDEOHV,WHP LQ)LJ
These sockets are used to supply the necessary voltages and compressed air to the component
changeover tables. The terminals for the safety and signalling circuits are also integrated into
these sockets. This prevents the placement system being started up before the component tables
are docked. If the component table is not connected, the protective contactor combination trips
and deactivates all the modules.

User Manual HS-50 2 Operational Safety
Software-Version 5.01Edition 01/99 2.2 Safety equipment
67
3XVKEXWWRQIRUUDLVLQJDQGORZHULQJWKHFRPSRQHQWFKDQJHRYHUWDEOHV,WHPLQ)LJ
To use this push-button, and thus the drives for the component table, you must first move the pla-
cement head out of the range of the component table and open the flap over the button. After
changing the component table, you must close the flap over the button once more.
– If the flap is closed, the safety circuit contact will close and the signalling contact will open. The
machine is then ready for use.
– If the flap is open, the safety circuit is interrupted and the signalling contact closes. An error
message will appear on screen, prompting you to close the flap. The machine can then be re-
started using the Start buttons.
8QLQWHUUXSWLEOHSRZHUVXSSO\836VWDWLRQFRPSXWHU,WHP LQ)LJ
Both the UPS and the station computer are housed beneath the input conveyor.
WARNING Always follow the safety instructions concerning potentially lethal volta-
ges - even when the placement system is switched off.
6DIHW\FLUFXLWDQGVLJQDOOLQJFLUFXLW
6WUXFWXUHRIWKHVDIHW\FLUFXLW
The following contacts are connected in series and form the safety circuit loop:
– make contacts for the four protective cover switches
– make contacts for the two PCB conveyor covers
– make contacts for the two emergency stop mushroom-head push-buttons
– make contacts for the four component tables
– make contacts for the four flaps over the push-buttons for raising and lowering the component
tables
– channels 2 and 3 of the protective contactor combination (PCC)
If the safety loop is closed, 24 VDC is present at channels 2 and 3 of the PCC. The two green
LEDs for channels 2 and 3 light up in addition to the green power ON LED.
6WUXFWXUHRIWKHVLJQDOOLQJFLUFXLW
The six signalling contacts for the covers are connected in parallel and form the "Cover signal"
circuit. If one or more covers are opened, the contacts close - the 24 V signal reaches the CAN
bus and signals that one of the covers is open.
The two signalling contacts for the emergency stop mushroom-head push-button are connected
2 Operational Safety User Manual HS-50
2.2 Safety equipment Software-Version 5.01 Edition 01/99
68
in parallel and form the "Emergency stop mushroom-head push-button signal" circuit. When an
emergency stop mushroom-head push-button is pressed, a 24 V signal is sent to the CAN bus
and signals that one of the emergency stop mushroom-head push-buttons has been pressed.
The four signalling contacts for the push-button flaps are connected in parallel. They form the
"Flaps signal" circuit. If one or more flaps is raised, a 24 V signal is applied to the CAN bus and
signals that one of the cover flaps is not closed.
The four signalling contacts for the component tables are connected in series and form the "Com-
ponent table signal" loop. If a component table is missing, a 0 V signal is sent to the CAN bus. If
all the tables are connected, the signal is approximately 16 V.
)XQFWLRQDOGHVFULSWLRQRIWKHVDIHW\FLUFXLW
The following conditions must be fulfilled before the placement system can be started or oper-
ated:
– all four component changeover tables must be docked and connected.
– all covers - four over the gantries, one over the PCB input belt and one over the output belt -
must be closed.
– both emergency stop mushroom-head push-buttons must be released
– all four flaps over the push-buttons for raising and lowering the component changeover tables
must be closed.
– the minimum operating pressure must have been reached.
– the software enable must have been given, thus activating the safety circuit.
– the power supply must be sending 24 V to the Start buttons and the protective contactor com-
bination.
– If one of the Start buttons is now pressed, the protective contactor combination (PCC) will
switch and activate the following components:
– 200 V link voltage for the servo amplifier for the gantry axes
– 100 V link voltage for the star axes
– 230 V operating voltage for the lifting table motors
– the servo unit will receive a "Servo enable" signal for the servo amplifier
– 34 V operating voltage is switched to the component changeover tables
– 24 V operating voltage is switched to the used tape cutters.
The machine is now ready for service.