00193922-03.pdf - 第115页

User manual SIPLAC E HF series 3 Technical data Software Vers ion SR.50x.xx 01/2006 US Edition 3.7 Placement heads 115 3.7 Placement heads 3.7.1 Head modularity One particul ar advan tage of the SIP LACE HF series is its…

100%1 / 374
3 Technical data User manual SIPLACE HF series
3.6 Overview of the modules Software Version SR.50x.xx 01/2006 US Edition
114
3.6 Overview of the modules
3
Fig. 3.6 - 1 HF/3 machine - protective covers and cover
(1) Machine frame
(2) PCB conveyor (flexible dual conveyor)
(3) Extension kit on the PCB input side
(4) Component trolley docking unit, tape cutter, used tape channel (4x)
(5) Gantry 1 with placement head (HF and HF/3)
(6) Extension kit on the PCB output side
(7) Gantry 3 with placement head (HF and HF/3)
(8) Monitor (2x)
(9) Keyboard (2x)
(10) Gantry 4 with placement head (HF/3)
User manual SIPLACE HF series 3 Technical data
Software Version SR.50x.xx 01/2006 US Edition 3.7 Placement heads
115
3.7 Placement heads
3.7.1 Head modularity
One particular advantage of the SIPLACE HF series is its head modularity. For example, the
placement heads on the gantries can be quickly changed and adapted to the placement require-
ments. 3
3.7.1.1 Placement head configuration on the HF placement machine
3
3
Fig. 3.7 - 1 Head modularity - SIPLACE HF
Placement area 1, gantry 1 Placement area 2, gantry 3
Placement head C&P12 C&P12
C&P12 C&P6
C&P12 TH
C&P6 C&P6
C&P6 TH
TH TH
Gantry 3
Gantry 1
TH
C&P12
C&P6
C&P12
C&P6
TH
Placement area 2
Placement area 1
3 Technical data User manual SIPLACE HF series
3.7 Placement heads Software Version SR.50x.xx 01/2006 US Edition
116
3.7.1.2 Placement head configuration on the HF/3 placement machine
3
Fig. 3.7 - 2 Head modularity - SIPLACE HF/3
3
Placement area 1 Placement area 2
Gantry 1 Gantry 4 Gantry 3
Placement head C&P12 C&P12 C&P12
C&P12 C&P12 C&P6
C&P12 C&P12 TH
C&P12 C&P6 C&P6
C&P12 C&P6 TH
C&P6 C&P12 C&P6
C&P6 C&P12 TH
C&P6 C&P6 C&P6
C&P6 C&P6 TH
Gantry 3
Gantry 1
TH
Gantry 4
C&P12
C&P6
C&P6
C&P12
C&P12
C&P6
Placement area 2