7 Station extensions User manual SIPLA CE HF series 7.1 Nozzle changer Software Version SR.50x.xx 01/2006 US E dition 292 W ARNING 7 Only in stall the as sociate d nozz le chang er for ea ch placem ent head . There is a …

100%1 / 374
User manual SIPLACE HF series 7 Station extensions
Software Version SR.50x.xx 01/2006 US Edition 7.1 Nozzle changer
291
7 Station extensions
7.1 Nozzle changer
Nozzle changers can greatly increase the flexibility of the placement heads for processing differ-
ent types of component. If the placement program requires a nozzle change, then the placement
head automatically returns the old nozzle to the nozzle holder and picks up the new nozzle. Noz-
zles that were separated out during the vacuum check can also be quickly changed.
It is significantly more exact and faster to pick up nozzles from a nozzle changer than would be
possible manually. When placing small components, it is essential to minimize the radial eccen-
tricity during nozzle rotation.
7.1.1 Nozzle changer for the 12-segment Collect&Place head
Item no. 00119661-xx
7
Fig. 7.1 - 1 Nozzle changer for the 12-segment Collect&Place head
This nozzle changer can hold up to 5 magazines, each with 12 nozzle holders. The magazines
are seated on a common support. They are centered using two parallel pins and fixed in place with
clips.
7 Station extensions User manual SIPLACE HF series
7.1 Nozzle changer Software Version SR.50x.xx 01/2006 US Edition
292
WARNING 7
Only install the associated nozzle changer for each placement head. There is a risk of head
crashes with mixed configurations.
7.1.1.1 Position of the nozzle changers for the C&P12 head on the HF machine
1 or 2 nozzle changers may be installed at locations 1 and 3 for the 12 segment Collect&Place
head (items 1 and 2 in Fig. 7.1 - 2
). A nozzle changer may be installed at locations 2 and 4. This
gives a total capacity of 6 nozzle changers with 30 magazines and a total of 360 nozzle holders.
7
Fig. 7.1 - 2 Position of the nozzle changer for the 12-segment Collect&Place head on the HF machine
7
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles
(5) Nozzle magazine
User manual SIPLACE HF series 7 Station extensions
Software Version SR.50x.xx 01/2006 US Edition 7.1 Nozzle changer
293
7.1.1.2 Position of the nozzle changers for the C&P12 head on the HF/3 machine
1 or 2 nozzle changers may be installed at locations 1, 3, and 4 for the 12 segment Collect&Place
head (items 1 and 2 in Fig. 7.1 - 3
). One nozzle changer may be installed at location 2. This gives
a total capacity of 7 nozzle changers with 35 magazines and a total of 420 nozzle holders.
7
Fig. 7.1 - 3 Position of the nozzle changer for the 12-segment Collect&Place head on the HF/3 machine
7
(1) Nozzle changer, "row 1"
(2) Nozzle changer, "row 2"
(3) Reject bin for components
(4) Take-off device and reject bin for nozzles
(5) Nozzle magazine