00193922-03.pdf - 第199页

User manual SIPLAC E HF series 4 Setting up and commissioning Software Vers ion SR.50x.xx 01/2006 US Edition 4.4 Setting up the placement machine 199 4.4.9 Fitting the inp ut conveyor 4.4.9.1 T ools – All en keys , DIN 9…

100%1 / 374
4 Setting up and commissioning User manual SIPLACE HF series
4.4 Setting up the placement machine Software Version SR.50x.xx 01/2006 US Edition
198
4.4.8.5 Fitting the axis unit
Æ Carefully lift the axis unit onto the rail in the extension kit.
Æ Make sure that you do not squash any cables.
Æ Push the axis unit into the extension kit as far as the stop.
Æ Secure the axis unit with the fillister head screw.
Æ Insert the cover.
Æ Fix the grounding cable to the doors (item 2 in Fig. 4.4 - 8, page 188), as shown in Fig.
4.4 - 10
on page 192.
Æ Lock the doors.
4.4.8.6 Fitting the side plates
Æ Fix the grounding cable to each side plate (item 6 in Fig. 4.4 - 8, page 188), as shown in Fig.
4.4 - 10
page 192.
Æ Fix the side plate to the machine frame with 6 fillister head screws.
PLEASE NOTE
If you have dismantled the output conveyor, continue from section 4.4.9
" Fitting the input con-
veyor" on page 199.
Once the input conveyor is fitted, then continue the assembly work from section 4.4.13
"Fitting
the main fault indicator" on page 214.
User manual SIPLACE HF series 4 Setting up and commissioning
Software Version SR.50x.xx 01/2006 US Edition 4.4 Setting up the placement machine
199
4.4.9 Fitting the input conveyor
4.4.9.1 Tools
Allen keys, DIN 911, set
Phillips screwdriver, size 1
4.4.9.2 Assembly
4
Fig. 4.4 - 14 Input conveyor - dual conveyor
(1) Panel, input conveyor
(2) Panel, processing conveyor 1
(3) Cable cover 20 x 200
(4) Countersunk screw, ISO 7046, M3x6, 2x per cable cover
(5) Cable cover 20 x 310
(6) Fillister head screw DIN 912, M3x5, 1x per cable cover
(7) Fillister head screw DIN 912, M6x16, and washer, 4x per panel
(8) Guide for hexagonal shaft
(9) Hexagonal shaft (single conveyor: one, dual conveyor: two)
(10) Drive unit
4 Setting up and commissioning User manual SIPLACE HF series
4.4 Setting up the placement machine Software Version SR.50x.xx 01/2006 US Edition
200
Æ Remove the cable covers (items 3 and 5 in Fig. 4.4 - 14) from the input conveyor (item 1 in
Fig. 4.4 - 14
).
Æ Carefully place the panel (item 1 in Fig. 4.4 - 14) against the panel on the processing conveyor
(item 2 in Fig. 4.4 - 14
).
CAUTION 4
Be careful not to cut through any of the light barrier or drive motor cables.
Æ Fix each panel using 4 fillister head screws M6x16 and the associated washers (item 7 in Fig.
4.4 - 14
).
Æ Connect the power cable to the light barriers and drive motors.
Æ Fix the cable covers in place (item 3 and 5 in Fig. 4.4 - 14).
Æ Introduce the hexagonal shaft (item 9 in Fig. 4.4 - 14) into the drive unit (item 10 in Fig. 4.4 -
14).
Æ Make sure that the hexagonal shaft guide (item 8 in Fig. 4.4 - 14) always points towards the
conveyor side wall to which the drive unit (item 10 in Fig. 4.4 - 14
) is fixed.