4 Setting up and commissioning User manual SIPLACE HF series 4.4 Setting up the placement machine Software Version SR.50x .xx 01/2006 US Edition 192 4.4.7.5 F itting the g rounding cable for t he doors Æ Fix the two grou…

User manual SIPLACE HF series 4 Setting up and commissioning
Software Version SR.50x.xx 01/2006 US Edition 4.4 Setting up the placement machine
191
Æ Introduce the mandrel (item 5 in Fig. 4.4 - 9) of the conveyor cover into the hole (item 6 in Fig.
4.4 - 9
) in the second half of the extension kit.
Æ Position the second half of the extension kit so that the assembly bracket lies on the assembly
bar (item 7 in Fig. 4.4 - 8
).
Æ Fix the second half of the machine using 2 fillister head screws M6x16 and washers (item 3
in Fig. 4.4 - 8
).
4.4.7.3 Fixing the hexagonal shaft guide
Æ On the single conveyor, fix
one
guide for the hexagonal shaft (item 8 in Fig. 4.4 - 7) to the
extension kit using two fillister head screws M6x16 and washers.
Æ On the double conveyor, fix two guides for the hexagonal shaft (item 8 in Fig. 4.4 - 7) to the
extension kit using two fillister head screws M6x16 and washers.
4
4.4.7.4 Connecting the power cables - Extension kit on the PCB output side
4
4
4
4
4
Left-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
Emergency stop button
Start/Stop button
X63/03020687 X63/03002526
Protective cover switch, location 3 X53/03020409 X53/03002528
Button for the component trolley docking unit,
location 3
X232/03021056 X232/03021053
Right-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
Start/Stop button
Switch, PCB conveyor cover
X62/03020410 X62/03002525
Protective cover switch, location 2 X52/03006476 X52/03002527
Button for the component trolley docking unit,
location 2
X222/03021056 X222/03021052

4 Setting up and commissioning User manual SIPLACE HF series
4.4 Setting up the placement machine Software Version SR.50x.xx 01/2006 US Edition
192
4.4.7.5 Fitting the grounding cable for the doors
Æ Fix the two grounding cables for the doors (item 4 in Fig. 4.4 - 8) to the machine frame as
follows:
4
Fig. 4.4 - 10 Fitting the grounding cable
4
4
4
4
4
4.4.7.6 Checking and setting the protective cover switch
Æ Check that the protective cover switch (item 7 in Fig. 4.4 - 9, page 190) is working correctly.
Æ Adjust the protective cover switch if necessary (see Service Manual).
Hex nut M5
Spring washer M5, DIN 7980
Washer M5, DIN 125
Cable lug, annular
Contact washer

User manual SIPLACE HF series 4 Setting up and commissioning
Software Version SR.50x.xx 01/2006 US Edition 4.4 Setting up the placement machine
193
4.4.7.7 Installing the "bottom" hand guard
The machines from the HF series are supplied with just
one
"bottom" hand guard. If the machines
are installed within a line, then no hand guard is required between immediately adjacent output
and input conveyors.
WARNING
Always fit the "bottom" hand guard (item no. 03003432-01) on the input side of the
first
place-
ment machine and on the output side of the
last
placement machine of a line using 4 hexagon
socket head screws M4x12. This will prevent your personnel reaching into the machine without
authorization.
4
Fig. 4.4 - 11 Fitting the "bottom" hand guard on the PCB output side
(1) "Bottom" hand guard, item no. 03003432-01