00193922-03.pdf - 第132页
3 Technical data User manual SIPLACE HF series 3.8 Electrical and pneumat ic connection points Software Vers ion SR.50x.xx 01/2006 US Edition 132 3.8 Electrical and pneum a tic connection point s 3.8.1 Electrical connect…

User manual SIPLACE HF series 3 Technical data
Software Version SR.50x.xx 01/2006 US Edition 3.7 Placement heads
131
3.7.4.3 Technical data
3
3
3
*) Please note that the component range that can be placed is also affected by the pad geometry, the customer-specific
standards and the packaging tolerances.
**) If standard nozzles are used
Optical centering with Stationary P&P component vision
camera (type 22) 50 x 40
Stationary P&P component vision
camera (type 20) 8 x 8
Component range *) 0603 to SO, PLCC, QFP, BGA, special
components, bare dies, flip-chips
0201 to SO, PLCC, QFP, sockets,
plugs, BGA, special components,
bare dies, flip-chips, shields
Component specification
max. height
min. lead pitch
min. ball pitch
min. ball diameter
min. dimensions
max. dimensions
max. weight
25 mm (higher available on request)
0.4 mm
0.56 mm
0.32 mm
1.6 x 0.8 mm²
50 x 40 mm² (single measurement)
For use with two nozzles:
50 x 50 mm² or
69 x 10 mm ²
For use with one nozzle:
85 x 85 mm² or
125 x 10 mm²
Up to 200 x 125 mm² (with restrictions)
100 g **)
25 mm (higher available on request)
0.25 mm
0.14 mm
0.08 mm
0.6 x 0.3 mm²
8 x 8 mm² (single measurement)
100 g **)
Programmable set-down
force
1.0 N - 15 N 1.0 N - 15 N
Nozzle types 5 xx (standard)
4 xx + adapter
8 xx + adapter
9 xx + adapter
5 xx (standard)
4 xx + adapter
8 xx + adapter
9 xx + adapter
Nozzle spacing on the two
Pick&Place heads
70.8 mm 70.8 mm
X/Y accuracy ± 26 µm / 3 σ, ± 35 µm / 4 σ ± 22 µm / 3 σ, ± 30 µm / 4 σ
Angular accuracy ± 0.05° / 3 σ, ± 0.07° / 4 σ ± 0.05° / 3 σ, ± 0.07° / 4 σ

3 Technical data User manual SIPLACE HF series
3.8 Electrical and pneumatic connection points Software Version SR.50x.xx 01/2006 US Edition
132
3.8 Electrical and pneumatic connection points
3.8.1 Electrical connection points
3
Fig. 3.8 - 1 Electrical connection points on the placement machine
3
(1) Main power switch
(2) Cover over the power supply unit
(3) Power supply unit
(4) Angle for the cable gland
(5) Power cable
(T) Direction of PCB transport

User manual SIPLACE HF series 3 Technical data
Software Version SR.50x.xx 01/2006 US Edition 3.8 Electrical and pneumatic connection points
133
3.8.2 Pneumatic connection point
3
Fig. 3.8 - 2 Pneumatic connection point on the placement machine
3
(1) Pneumatic unit
(2) Coupling for connecting the compressed air hose
(3) Stop valve
(4) Recess for the air hose
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 3