2OM-1011-002.pdf - 第103页
0305-001 Tg0858-PM-PM 3.2 Example 2 (Example of Placement Data Creation) (2) Example of Data Creation • Use the following placement data. Placement Data (P) U01, (O) U01, and (V) U01 (P) U02, (O) U02, and (V) U02 (P) U03…

0305-001 Tg0858-PM-PM
3.2 Example 2 (Example of Placement Data Creation)
Fig. 2B130
Notes: (a) P
0
shows the P.C.B. positioning reference.
(b) “O-0001, O-0002, and O-0003 for Model A”, “O-0001, O-0002,
and O-0003 for Model B”, and “O-0001 for Model C” are called
“Pattern Origins”. Each coordinate measured from the P.C.B. po-
sitioning reference point must be entered.
(c) Measure the coordinates (distances) based on the pattern origins
and enter them for component placement.
(d) Measure the coordinates (distances) of the fiducial marks based
on the pattern origins and enter them.
2-83
Fig. 2B129

0305-001 Tg0858-PM-PM
3.2 Example 2 (Example of Placement Data Creation)
(2) Example of Data Creation
• Use the following placement data.
Placement Data (P) U01, (O) U01, and (V) U01
(P) U02, (O) U02, and (V) U02
(P) U03, (O) U03, and (V) U03
• P.E.C. recognition must be specified for each individual repetitive pat-
terns in the operation data.
Set “ON” in the “P.E.C. RECOGNITION” and “ON” in the “IMAGE”
data box of the label “P.E.C. RECOGNITION MODE”.
Note: Data for Model C must be created as repetitive pattern for one unit
P.C.B. because the P.E.C. recognition function (global) is implemented
according to the repetitive pattern program data created for a unit P.C.B.
Plecemnt Data (P) U01
2-84
Enter “0” (zero) in all data fields of the last step and “P” or
“Q” as a control command.
Plecemnt Data (O) U01
Enter “0” (zero) in all data fields of the last step and “E”
as a control command.
Plecemnt Data (V) U01
Notes: (a) The mark code Nos. registered in the “MARK DATA” data boxes
at the “OPERATION DATA” display must be entered in the “F1”
and “F2” data fields.
(b) V-0001, V-0002, V-0003 ... These Nos. correspond to the place-
ment steps.
Do not enter any parameter unless the marks at the placement
position for each individual components should be recognized.
P-NO. X(mm) Y(mm) Z(THETA) H(mm) FDR S V C COMMENT
0000 +0.00 +0.00 +0°00’ +0.00 000 - 02 -
0001 +5.00 +20.00 +0°00’ +0.00 101 - 00 -
0002 +15.00 +10.00 +180°00’ +0.00 201 - 00 -
0003 +25.00 +10.00 +90°00’ +0.00 301 - 00 -
0004 +0.00 +0.00 +0°00’ +0.00 000 - 00 P
O-NO. X(mm) Y(mm) Z(THETA) H(mm) C COMMENT
0000 +0.00 +0.00 +0°00’ +0.00 -
0001 +5.00 +5.00 +0°00’ +0.00 -
0002 +35.00 +5.00 +0°00’ +0.00 -
0003 +65.00 +5.00 +0°00’ +0.00 -
0004 +0.00 +0.00 +0°00’ +0.00 E
V-NO. V X1(mm) Y1(mm) F1 X1(mm) Y1(mm) F2 C
0000 02 +5.00 +5.00 01 +25.00 +25.00 01 -
0001 00 +0.00 +0.00 00 +0.00 +0.00 00 -
0002 00 +0.00 +0.00 00 +0.00 +0.00 00 -
0003 00 +0.00 +0.00 00 +0.00 +0.00 00 -
0004 00 +0.00 +0.00 00 +0.00 +0.00 00 P
Table 2B30
Table 2B31
Table 2B32

0305-001 Tg0858-PM-PM2-85
Placement Data (P) U02
3.2 Example 2 (Example of Placement Data Creation)
Enter “0” (zero) in all data fields of the last step and “P” or
“Q” as a control command.
Placement Data (O) U02
Enter “0” (zero) in all data fields of the last step and “E”
as a control command.
Placement Data (V) U02
Notes: (a) The mark code Nos. registered in the “MARK DATA” data boxes
at the “OPERATION DATA” display must be entered in the “F1”
and “F2” data fields.
(b) V-0001, V-0002, V-0003 ... These Nos. correspond to the place-
ment steps.
Do not enter any parameter unless the marks at the placement
position for each individual components should be recognized.
P-NO. X(mm) Y(mm) Z(THETA) H(mm) FDR S V C COMMENT
0000 +0.00 +0.00 +0°00’ +0.00 000 - 02 -
0001 +20.00 +5.00 +90°00’ +0.00 301 - 00 -
0002 +50.00 +10.00 +270°00’ +0.00 401 - 00 -
0003 +70.00 +10.00 +0°00’ +0.00 601 - 00 -
0004 +0.00 +0.00 +0°00’ +0.00 000 - 00 P
O-NO. X(mm) Y(mm) Z(THETA) H(mm) C COMMENT
0000 +0.00 +0.00 +0°00’ +0.00 -
0001 +5.00 +40.00 +0°00’ +0.00 -
0002 +5.00 +55.00 +0°00’ +0.00 -
0003 +5.00 +70.00 +0°00’ +0.00 -
0004 +0.00 +0.00 +0°00’ +0.00 E
V-NO. V X1(mm) Y1(mm) F1 X1(mm) Y1(mm) F2 C
0000 02 +5.00 +10.00 02 +85.00 +10.00 02 -
0001 00 +0.00 +0.00 00 +0.00 +0.00 00 -
0002 00 +0.00 +0.00 00 +0.00 +0.00 00 -
0003 00 +0.00 +0.00 00 +0.00 +0.00 00 -
0004 00 +0.00 +0.00 00 +0.00 +0.00 00 P
Table 2B33
Table 2B34
Table 2B35