2OM-1011-002.pdf - 第43页

[SCREENS] Key When this key is pressed, another “P .E.C. MARK DA T A EDIT” display appears on the screen. [PROGRAM CHECK] Key When this key is pressed, the edited pattern program is checked. [THROUGH HOLE MARK DA T A] Ke…

100%1 / 271
0305-001 Tg0858-PM-PM
FIDUCIAL MARK #1
X LCTN. (Horizontal) and Y LCTN. (Vertical)
Set the coordinates of the first fiducial mark for the P.E.C.
global recognition function. (Unit: mm)
MARK CODE
Set the code No. of the first fiducial mark for the P.E.C. global
recognition function.
Select one of the 10 mark codes registered in the P.E.C.
mark data.
FIDUCIAL MARK #2
X LCTN. (Horizontal) and Y LCTN. (Vertical)
Set the coordinates of the second fiducial mark for the P.E.C.
global recognition function. (Unit: mm)
MARK DATA
Set the code No. of the second fiducial mark for the P.E.C.
global recognition function.
Select one of the 10 mark codes registered in the P.E.C.
mark data.
FIDUCIAL MARK #3
X LCTN. (Horizontal) and Y LCTN. (Vertical)
Set the coordinates of the third fiducial mark for the P.E.C.
global recognition function. (Unit: mm)
MARK DATA
Set the code No. of the third fiducial mark for the P.E.C. glo-
bal recognition function.
Select one of the 10 mark codes registered in the P.E.C.
mark data.
[P.E.C. MARK DATA EDIT] Key
Press this key to shift to the display for P.E.C. mark data (mark
type, size, etc.) editing.
2.3 OPERATION DATA Display
2-23
Fig. 2B44
Fig. 2B45
Fig. 2B46
Fig. 2B47
[SCREENS] Key
When this key is pressed, another “P.E.C. MARK DATA EDIT”
display appears on the screen.
[PROGRAM CHECK] Key
When this key is pressed, the edited pattern program is checked.
[THROUGH HOLE MARK DATA] Key
When this key is pressed, a display related to the through hole
marks (marks which belong to the selected type) appears on
the screen.
[PAD MARK DATA] Key
When this key is pressed, a display related to the pad marks
(marks which belong to the selected type) appears on the screen.
[MORE MARK TYPES] Key
When this key is pressed, other mark types in the same cat-
egory are recalled.
[1] Key
[SCREENS] Key
Fig. 2B48
Fig. 2B50
Fig. 2B49
2.3 OPERATION DATA Display
2.3.3 P.E.C. MARK DATA EDIT Display
When the [P.E.C. MARK DATA EDIT] key is pressed at the “OPERATION
DATA 02/03” display (Fig. 2B10), the following display appears on the screen.
Pressing the [SCREENS] key at this display opens another “P.E.C. MARK
DATA EDIT” display.
When the [1] key under the label “MARK DATA” is pressed, the display (Fig.
2B50) appears on the screen, enabling the editing of P.E.C. mark data.
0305-001 2-24
Tg0858-PM-PM
Fig. 2B55
Fig. 2B51
Fig. 2B52
Fig. 2B53
Fig. 2B54
MARK SIZE D1 (mm), D2 (mm), D3 (mm)
“D3 (mm)” is reserved data.
Set the outer and inner diameters of a fiducial mark.(Unit: mm)
Refer to “(1) Type and Size” in “2.3.4 P.E.C. Fiducial Marks
of Section 2” for details.
WINDOW SIZE
Set the window size (recognition area) for the P.E.C. recogni-
tion function. (Unit: mm)
Set a preferably small value to avoid false recognition and
shorten recognition time.
MARK DATA
The mark data (code) corresponds to the code No. of the fidu-
cial mark used in the P.E.C. recognition function.
10 types of mark codes can be registered for each program
data.
MARK TYPE
Shown is the selected type of fiducial mark.
Marks are categorized according to the following three types
- “P.E.C. Mark”, “Through Hole”, and “Pad Mark”.
2.3 OPERATION DATA Display
<Pad Mark>
<Through Hole>
<P.E.C. Mark>
Fig. 2B60
0305-001 2-25
Tg0858-PM-PM
Fig. 2B56
Fig. 2B57
Fig. 2B58
Fig. 2B59