0305-001 Tg0858-PM-PM 3.2 Example 2 (Example of Placement Data Creation) (2) Example of Data Creation • Use placement data (P) U01. • Do not enter any parameters in placement data (O) because it is not used. When it is n…

100%1 / 271
0305-001 Tg0858-PM-PM
3.2 Example 2 (Example of Placement Data Creation)
3.2.2 Normal Placement Data
[To set the P.E.C. recognition function for each
individual components]
(1) Pattern Sample
The figure below shows an example of placing three components on
the P.C.B.
2-74
Fig. 2B118
Notes: (a) P
0
shows the P.C.B. positioning reference.
(b) The placement coordinates of a component are measured based
on the P.C.B. positioning reference (0, 0).
(c) The fiducial mark position of a component is measured based on
the P.C.B. positioning reference (0, 0).
0305-001 Tg0858-PM-PM
3.2 Example 2 (Example of Placement Data Creation)
(2) Example of Data Creation
Use placement data (P) U01.
Do not enter any parameters in placement data (O) because it is not
used.
When it is not necessary to perform any P.E.C. recognition on each
individual components, do not set any parameters as placement data
(V).
P.E.C. recognition must be specified for each individual components
in the operation data.
(Set “ON” in the “P.E.C. RECOGNITION” and “ON” in the “LOCAL”
data box of the label “P.E.C. RECOGNITION MODE”.)
PLACEMENT DATA (P) U01
2-75
Enter “0” (zero) in all data fields of the last step and “E” as
a control command.
(Component placement is not implemented for the step
where a control command other than “-” and “D” is
entered.)
PLACEMENT DATA (V) U01
Note: The mark code Nos. registered in the “MARK DATA” data boxes at
the “OPERATION DATA” display must be entered in the “F1” and
“F2” data fields.
In this example, the 2-point recognition is applied to steps 0001 and
0002, using the mark (mark code 01). The 1-point recognition is imple-
mented for step 0003, using the mark (mark code 02).
P-NO. X(mm) Y(mm) Z(THETA) H(mm) FDR S V C COMMENT
0000 +0.00 +0.00 +0°00’ +0.00 000 - 00 -
0001 +10.00 +25.00 +0°00’ +0.00 101 - 02 -
0002 +20.00 +15.00 +180°00’ +0.00 201 - 02 -
0003 +30.00 +25.00 +90°00’ +0.00 301 - 01 -
0004 +0.00 +0.00 +0°00’ +0.00 000 - 00 E
V-NO. V X1(mm) Y1(mm) F1 X2(mm) Y2(mm) F2 C
0000 00 +0.00 +0.00 00 +0.00 +0.00 00 -
0001 02 +6.00 +29.00 01 +14.00 +21.00 01 -
0002 02 +24.00 +19.00 01 +16.00 +11.00 01 -
0003 01 +30.00 +25.00 02 +0.00 +0.00 00 -
0004 00 +0.00 +0.00 - +0.00 +0.00 - E
Table 2B23
Table 2B24
0305-001 Tg0858-PM-PM
3.2 Example 2 (Example of Placement Data Creation)
3.2.3 Repetitive Placement Data
[Not to set the P.E.C. recognition function for each individual
repetitive patterns]
(1) Pattern Sample
The figure below shows components placed on each unit P.C.B. mak-
ing the same patterns (4 patterns) repeatedly.
2-76
Fig. 2B120
Fig. 2B119