0305-001 Tg0858-PM-PM 2-20 2.3 OPERA TION DA T A Display [2-Point Recognition] Fig. 2B36 • Specify fiducial mark positions so that one fiducial mark is kept as diagonally away from the other as possible. Note: A void fid…

100%1 / 271
0305-001 Tg0858-PM-PM
[BEFORE PU]
The P.E.C. recognition function is performed before a com-
ponent is picked up.
This parameter should be selected when the P.E.C. recog-
nition function cannot be performed with a component be-
ing picked up.
P.E.C. RECOGNITION MODE GLOBAL
Set one of the following options to set the number of recogni-
tion points for the P.E.C. global recognition function.
“OFF”
“1PT.”
“2PT.”
“3PT.”
[1-Point Recognition]
2.3 OPERATION DATA Display
Fig. 2B35
Only the X and Y elements are corrected. The θ element
(expansion, etc.) is not corrected.
2-19
Fig. 2B34
Reference
When “AFTER PU” is set in the data box, a component is
picked up and the component recognition is performed on
the component while the P.C.B. is being transferred to the
P.C.B. positioning section.
Since the component is already picked up, it can be placed
soon after the component and P.E.C. recognition functions
are performed. Because the loss time (waiting time)
decreases, there is an effect to shorten the time to finish a
P.C.B.
0305-001 Tg0858-PM-PM2-20
2.3 OPERATION DATA Display
[2-Point Recognition]
Fig. 2B36
Specify fiducial mark positions so that one fiducial mark is
kept as diagonally away from the other as possible.
Note: Avoid fiducial mark positions where the X and Y ele-
ments are the same. See Fig. 2B37 below.
Fig. 2B37
[3-Point Recognition]
Fig. 2B38
Specify fiducial mark positions so that the triangle area
formed by connecting the three points (three fiducial marks)
becomes as large as possible.
Note: When any two of the three fiducial marks are desig-
nated to be positioned as close as possible to each other,
the results of the correction will be almost the same as
“2-Point Recognition” because the bend, expansion,
etc., of P.C.B. are detected as even occupants of the X
and Y elements.
In other words, the bend, expansion, etc., of P.C.B. oc-
cupying the X and Y elements unevenly will cause
wrong correction result.
0305-001 Tg0858-PM-PM
Fig. 2B40
Note: When the global recognition is used together with the
image recognition, both recognizing actions take place
but the placement coordinates are corrected according
to the result of the image recognition.
P.E.C. RECOGNITION MODE LOCAL
Set whether or not the fiduciary mark on each component place-
ment point should be recognized.
“OFF”
“ON”
1PT.: Put a fiducial mark on the center of component place-
ment point or a desired point around the center.
P.E.C. RECOGNITION MODE IMAGE
Set one of the following options to determine whether or not
the P.E.C. image recognition function should be performed.
“OFF”
“ON”
Note: The coordinates and mark data of a fiducial mark are
designated in the placement data (V).
2.3 OPERATION DATA Display
2-21
Fig. 2B42
Fig. 2B39
Fig. 2B41