00193631-0602.pdf - 第10页

1 Preface Adjustment Instructions MTC 2 1.2 Overview of the issues 12/2007 Edition 10

100%1 / 116
Adjustment Instructions MTC 2 1 Preface
12/2007 Edition 1.2 Overview of the issues
9
1.2 Overview of the issues
NOTE
We would like to draw your attention to the fact that the contents of these adjustment instructions
are not part of a previous or existing agreement, commitment or legal relationship, nor is this
intended to modify one of the above. All obligations of the company ASM AS may be taken
from the appropriate sales contract, which also contains complete and valid warranty agreement.
These contractual warranty conditions are neither expanded nor restricted by the contents of
these adjustment instructions.
Guide Software version Issue
First edition Adjustment Instructions SR.504.xx 03/2003
corrected edition Adjustment Instructions 05/2004
corrected edition Adjustment Instructions 12/2004
corrected edition Adjustment Instructions 03/2007
corrected edition Adjustment Instructions 12/2007
1 Preface Adjustment Instructions MTC 2
1.2 Overview of the issues 12/2007 Edition
10
Adjustment Instructions MTC 2 2 Operational safety
12/2007 Edition
11
2 Operational safety
NOTE
It is absolutely necessary to observe the chapter 'Operational safety' of the MTC 2 User Manual!
WARNING
No activities may be performed on the MTC 2 without precise knowledge of the User Manual User
Manual/ User Manual. All tasks must be carried out by trained and qualified members of staff. All
warning, caution and danger notes must be adhered to!
DANGER
The SIPLACE station and the MTC 2 are operated electrically. Parts of the installation carry
dangerous levels of voltage – even when switched off at the main switch. Applicable national
standards such as VDE, VDI and VGB must be observed.
You should always switch the machine off at the main switch, and isolate it from the power supply
before carrying out work on live parts. There is a risk of death, severe injury and/or considerable
damage to equipment even if only one of these instructions are not followed.
Observe the relevant accident prevention standards and the User Manual for the installation. This is
applies particularly to the travel ranges of the lifting and feed axes of the MTC 2.