80S-20用户手册.pdf - 第199页

SIPLACE 80S -20/F4 User Manual 5 Single functions Software version SR.407.xx 01/2001 US Edition 5.2 Single functions, gantry 199 5.2.8 "Nozzle changer configuration IC-head" view 5 Å In the current view for the…

100%1 / 570
5 Single functions SIPLACE 80S-20/F4 User Manual
5.2 Single functions, gantry Software version SR.407.xx 01/2001 US Edition
198
Confirm magaz. 5
This function is used to confirm that an individual magazine has been filled with a new nozzle
type.
When changing the set-up of a machine it may be necessary to change the type of nozzle in
some of the magazines. To do this, the current nozzle configuration (Actual) and the nozzle con-
figuration for the new set-up (Preset) is shown in the table for each of magazine. When you
change the nozzle type from the "Actual" to "Preset" type, you must confirm this for each maga-
zine separately.
Å Click the entry in the table which corresponds to the magazine for which you must change the
nozzle type. The line is now highlighted in light blue.
Å Click the Lock. op./close button.
Å Replace all the nozzles in this magazine with the nozzle type shown in the "Preset" column.
Å Click the Lock. op./close button again.
Å Click the Confirm magaz. button.
The change of is now confirmed. In the table, the arrow ( <== ) is no longer displayed next to
the entry for this magazine.
5
5
SIPLACE 80S-20/F4 User Manual 5 Single functions
Software version SR.407.xx 01/2001 US Edition 5.2 Single functions, gantry
199
5.2.8 "Nozzle changer configuration IC-head" view
5
Å In the current view for the single function for Gantry, click the symbol .
NOTE
The nozzle changer must be installed and configured in the machine options. When calling
this menu the nozzles on the placement head are returned to the nozzle changer. 5
The user interface is switched to the "Nozzle changer configuration IC-head" view (see
Fig. 5.2 - 8
). 5
5
Fig. 5.2 - 8 "Nozzle changer configuration IC-head" view
5 Single functions SIPLACE 80S-20/F4 User Manual
5.2 Single functions, gantry Software version SR.407.xx 01/2001 US Edition
200
5.2.8.1 General comments
The "Nozzle changer configuration IC head" view only provides the function for confirming the
nozzle configuration for the individual nozzle holders in the nozzle changer.
Click on the appropriate button to carry out the required function.
The nozzle changer configuration is displayed in the table in the display.
5
Conditions for changing the set-up of the nozzle changer
Remember the following points when changing the set-up: 5
Each of the nozzle holders can be set up with different nozzle types.
The maximum number of nozzles per magazine is 5.
The maximum number of magazines on a nozzle changer is 4.
Meaning of the entries in the table in the display
Garage
Number of the nozzle holder
Actual
Type of nozzles currently in the nozzle holder
Preset
If the type of nozzle currently in the nozzle holder is not the same as shown in this column, then
it is to be changed
To change
An arrow ( <== ) in this column indicates that the nozzle type currently in the nozzle holder
("Actual" column) must be changed for the nozzle type shown in the "Preset" column.