80S-20用户手册.pdf - 第40页

1 Introduction SIPLACE 80S-20 /F4 User Manual 1.6 The line conc ept Software version SR. 407.xx 01/2001 US E dition 40 1.6 The line concept 1.6.1 Ove rview The machine can be link ed to input/out put stations, scr een pr…

100%1 / 570
SIPLACE 80S-20/F4 User Manual 1 Introduction
Software version SR.407.xx 01/2001 US Edition 1.5 Description of the machine
39
1.5.5 Technical data overview of the SIPLACE 80F
4
Procedure Collect&place
Component range
Standard vision module from 0402 to 55mm x 55mm
Max. placement rate
12-segment Collect&Place head
Pick&Place head
10,000 components/hour
1,800 components/hour
12-segment Collect&Place head
Angular accuracy
Placement accuracy
± 0.525°/ 3 σ, ± 0.70°/ 4 σ, ± 1.05°/ 6 σ
± 67.5µm / 3 σ, 90µm / 4 σ, 135µm / 6 σ
± 45µm / 3 σ, 60µm / 4 σ, 90µm / 6 σ) **
Pick&Place head
Angular accuracy
Placement accuracy
± 0.052°/ 3 σ, ± 0.07°/ 4 σ, ± 0.105°/ 6 σ
± 37.5µm / 3 σ, 50µm / 4 σ, 75µm / 6 σ
PCB format 50mm x 50mm to 460mm x 460mm
(optionally 460mm x 508mm, 18" x 20")
Feeder capacity 40 locations for feeders
Component supply
Types of feeder
Changeover table, wafflepack changer, manual WPC
trays, component tapes, stick magazines, bulk cases
Operating system Microsoft Windows NT / RMOS
Connection In-line or stand alone
Space required 4 m² / module
1 Introduction SIPLACE 80S-20/F4 User Manual
1.6 The line concept Software version SR.407.xx 01/2001 US Edition
40
1.6 The line concept
1.6.1 Overview
The machine can be linked to input/output stations, screen printing systems, soldering ovens and
other machines from the SIPLACE range (HS-50, S-20, F
4
, F
5
/F
5
HM, and the SIPLACE G adhe-
sive application station). All SIPLACE modules are supplied with the necessary data by the UNIX
line computer. The placement machine can also be linked to a higher level data processing system
through the use of suitable interfaces. 1
1.6.2 Technical data line concept
1
*) SIPLACE HS-50, SIPLACE 80 S-20, SIPLACE 80 S-23 HM or SIPLACE 80 F
4
with 12-segment
Collect&Place head 1
**) SIPLACE 80 F
4
/F
5
/F
5
HM 1
1
1
System SIPLACE placement lines
Modules SIPLACE HS-50 / SIPLACE 80 S-20 / SIPLACE S-23 HM
SIPLACE 80 F
4
/ SIPLACE F
5
/ SIPLACE F
5
HM
Peripherals Input/output stations
Screen printers
Soldering ovens
Inspection stations, etc.
Component range From 0402 * to 55 mm x 55 mm **
PCB conveyor Automatic width adjustment
PCB format 50 mm x 50 mm to 460 mm x 460 mm
Placement rate Depends on how the modules are connected to one another
Space required 4 m² / SIPLACE 80 module
7.5 m² / SIPLACE HS-50 module
SIPLACE 80S-20/F4 User Manual 1 Introduction
Software version SR.407.xx 01/2001 US Edition 1.7 Electrical and pneumatic connection points
41
1.7 Electrical and pneumatic connection points
1
Fig. 1.7 - 1 Electrical and pneumatic connection points on the machine
(1) Compressed air unit
(2) Connection for compressed air line
(3) Main power filter Z1
(4) Hole for power cable
(5) Service socket
(6) Compressed air connection for changeover table
(7) Power supply connection for changeover table
(8) Communications connection for changeover table
(9) LAN supply in control unit
(10) Main switch